Fault
Inspection
The water keeps
Inlet valve
flowing into the
water tank.
Water level sensor
Leakage
Water inlet
Inlet pipe or drain
pipe
Ice making time is
Water supply
too long
pressure
Water
temperature
Ambient
temperature
Refrigerant
Inlet valve
Cause
Solution
The inlet valve
Replace the inlet
has an internal
valve.
leakage.
Water level
Contact
detection is not
constumer service.
sensitive.
Loose or not in
Tighten or reinstall
place
There is a rupture
Replace
that causes a leak.
Water pressure
Increase the water
is too low, water
pressure.
supply time is too
long every time.
Water
Reduce the water
temperature is too
temperature.
high.
Ambient
Place the machine
temperature is too
in a room with
high or too low.
an appropriate
temperature.
Refrigerant
Contact
leakage.
constumer service.
Leakage leads
Replace the inlet
to a long cooling
valve.
time.