Descargar Imprimir esta página

Technical Data - LaserLiner MultiMeter-Pocket Manual De Instrucciones

Ocultar thumbs Ver también para MultiMeter-Pocket:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Technical data

Function
DC voltage
AC voltage 40 - 400 Hz
DC current
AC current
Resistance
Max. input voltage
Diode test
Continuity test
Input resistance
Polarity
LCD
Fuse
Overvoltage
Pollution degree
Degree of protection
Operating conditions
Storage conditions
Power supply
Dimensions
Weight
Test standards
Subject to technical alterations. 18W39
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=ADX
MultiMeter-Pocket
Range
200 mV
2.000 V, 20.00 V, 200.0 V
600 V
2.000 V, 20.00 V
200.0 V, 600 V
200.0 A, 2000 A
20.00 mA, 200.0 mA
200.0 A, 2000 A
20.00 mA, 200.0 mA
600 V AC/DC
Test current 1 mA max., open circuit voltage of 1.5 V typical
Sign for negative polarity
Up to 1999 (3.5 segments)
mA, A range: 0.2 A/500 V
CAT III - 1000 V
2
IP 64
-10°C ... 55°C, Max. humidity 80% rH, no condensation,
max. altitude 2000 m
-10°C ... 60°C, Max. humidity 80% rH
2 x 1.5 V AAA (NEDA24A/IEC LR 03)
120 x 55 x 40 mm
145 g
EN 61326, EN 61010-1, EN 61010-2-031
Precision
± (0.5% rdg + 3 digits)
± (1.2% rdg + 3 digits)
± (1.0% rdg + 8 digits)
± (2.3% rdg + 10 digits)
± (2.0% rdg + 8 digits)
± (2.5% rdg + 10 digits)
± (0.8% rdg + 5 digits)
± (1.2% rdg + 5 digits)
± (5.0% rdg + 5 digits)
± (10.0% rdg + 5 digits)
EN
17

Publicidad

loading