Gas filling lower than 100 grams is not allowed, press OK then digit an higher amount of gas
filling.

Edit GAS FILLING mode:

Select the connection mode:
-
HP+LP fill the refrigerant from both HP and LP service ports
-
HP to fill the refrigerant only from the HP service port,
-
LP to fill the refrigerant only from the LP service port,

START AUTOMATIC PROCEDURE:

After selected all the procedure data, press OK to continue. If sanitizer is enabled, the following
screen will be displayed:
Select YES to perform a PURIFICATION during the AUTOMATIC PROCEDURE (refer to
Sanitizer instruction manual [MANU040.IGN]), or press NO to skip it, then the following screen
will be displayed:
Type the plate of the car, press OK to confirm. BACK to return back.
NOTE: the numerical keys include an alphabet that is used similar to text messaging; for
example: press "2" once to display "A", twice to display "B", three time for "C", four time for "2".
If gas analyzer is installed, The machine will test the purity of the refrigerant gas in the A/C
system before beginning recovery (refer to Gas analyzer instruction manual [MANU043.ANL].
Then SUMMARY SCREEN will be displayed:
INSTRUCTIONS MANUAL
R134a
AUTOMATIC PROCEDURE
WARNING !
Gas filling quantity
Less than 100g
Press OK to continue
GAS FILLING
R134a
AUTOMATIC PROCEDURE
Would you like to implement a PURIFICATION
during the AUTOMATIC PROCEDURE?
YES
NO
PURIFICATION
R134a
AUTOMATIC PROCEDURE
Inset vehicle
Plate number:
RECOVERY / RECYCLE
-35-