SPECIFICATIONS
Power supply
Liquid temp. range
Discharge size
Sump basin
Switch on/off
(SPP03301K)
Switch on/off
(SPP05001K)
INSTALLATION
1. Attaching the discharge pipe to the
pump discharge
Attach the discharge pipe to the pump discharge.
Drill an 1/8" anti-airlock hole as shown. The hole
must be in the sump.
NOTE: If the discharge pipe has thread, you can thread
the pipe into the pump discharge. If the discharge pipe
does not have thread, you can thread an adaptor (thread-
slip adaptor sold separately) into the pump discharge.
2. Connecting a check valve to the
discharge pipe
Install a check valve (not included) (1) in the vertical
discharge pipe (2). Be sure the flow is away from the
pump.
4
115V, 60 HZ., 15 Amp Circuit
32°F to 77°F (0°- 25°C)
SPP05001K: 1-1/2 in. FNPT or 1-
1/4 in. FNPT (with adaptor)
SPP03301K: 1-1/4 in. FNPT
Minimum 12 in. (30.4cm)
diameter,
18 in. (45.7cm) depth
Preset: On: 11 in. (280 mm), Off:
4.3 in. (110 mm)
Preset: On: 12.6 in. (320 mm),
Off: 4.7 in. (120 mm)
Float switch is factory preset to optimize performance and
product life.
Only adjust the float on and off position if necessary through
the steps below:
Step 1
Adjust theposition
Loosen the screw
ofthe lock washer
For Professional Technical Support call 1-844-242-2475
Step2
Step 3
Tighten the screw

Publicidad