TECHNICAL DATA

Power supply
Maximum absorbed power
Microwave power
Grill
Hot air
Microwave frequency
ELECTRICAL HOOK-UP
Before making the electrical hook-up, make
sure that:
• the characteristics of the electrical system
satisfy what is shown on the serial number
plate applied to the front of the oven;
• the electrical system has an effect earth
connection conforming to standards and
current law.
The earth connection is required by law.
The cable must not, at any point, reach a
temperature greater than 50 °C above the
ambient temperature.
This oven must be connected to the supply by
a supply cord fitted with an appropriately rated
plug that is compatible with the socket-outlet
fitted to the final sub-circuit in the fixed wiring
that is intended to supply this oven.
If a fixed appliance does not have a power
cord and plug, or another device that
ensures disconnection from the mains, with
an opening distance of the contacts that
allows complete disconnection under the
conditions of excessive voltage category III,
such disconnection devices must be provided
in the power supply mains conforming to the
installation rules.
The omnipolar socket or switch must be easy
to reach when the appliance is installed.
NOTE: The manufacturer declines all liability if
the usual accident prevention standards
and the above instructions are not
followed.
220-240 V~,
50 Hz
3200 W
900 W
1500 W
1500 W
2450 MHz
TYPE AND MINIMUM DIAMETER OF THE CABLES
H05RR-F
3x1,5 mm²
H05VV-F
3x1,5 mm²
H05RN-F
3x1,5 mm²
H05V2V2-F
3x1,5 mm²
SASO
H05RR-F
3x2,5 mm²
H05VV-F
3x2,5 mm²
H05RN-F
3x2,5 mm²
H05V2V2-F
3x2,5 mm²