3.8
HEAD AVAILABLE
TO SYSTEM
PT
Residual head for the heating system is
shown as a function of rate of flow in the
GB
graph in fig. 17.
To obtain the maximum head available to
the system, turn off the by-pass by turning
the union to the vertical position (fig. 17/a).
GR
3.9
ELECTRICAL WIRING
RO
OF ZONE HEATING SYSTEMS
When installing a system of this type, use a
separate electrical line to which room ther-
RUS
mostats with their local valves will be con-
nected.
Connect micro switches or relay contacts
on terminals 10-11 of the "TA" connector of
the electronic card after removing the exi-
sting jumper (fig. 18).
KEY
TA-TA1
Zone room stat
VZ-VZ1 Zone valve
R-R1
Zone relay
CR-CR1 Relay contact or micro zone valve
80
600
500
25 BF
25 OF
400
300
200
100
0
200
400
By-pass inserito
By-pass on
Connettore "TA"
"TA" connector
CR
CR
1
By-pass inserito
By-pass on
By-pass escluso
By-pass off
25 OF
25 BF
600
800
1000
1200
FLOW RATE (l/h)
PORTATA (l/h)
By-pass off
By-pass escluso
L
TA
VZ
R
VZ
1
N
NOTE: Relays are used only if the area