• Turn on the attachment by briefly pressing the ON button (9).
• Align the display center with the crosshairs of the reticle by tilting the
attachment.
• Align top and bottom display boundaries parallel to the horizontal axis of the
optical sight by turning the attachment clockwise or counterclockwise.
• Having reached the best possible position of the attachment, tighten two
screws (16) until stop. The clamping force should be 7 N·m (use a torque
screwdriver to check).
13
www.tulon.ru
Powering on and image setup
• Remove the lens cover (1) by turning it counterclockwise.
• Turn on the attachment by pressing the ON (9) button.
• Adjust a sharp resolution of symbols on the display by rotating the dioptre
adjusting ring on your optical sight. In future, it will not be necessary to
adjust the eyepiece dioptre, regardless of the distance and other conditions.
• Rotate the lens focus knob (10) to focus on the visual target.
• Enter the main menu with a long press of the MENU button (7) and select the
desired calibration mode: manual (M), semi-automatic (SA) or automatic (A).
• Calibrate the image by briefly pressing the ON button (9). Close the lens
cover when calibrating manually.
• Select the desired observation mode (Forest, Rocks, Identification or User)
by briefly pressing the MODE button (8) or in the main menu. User mode
allows you to change and save user brightness and contrast settings in the
quick menu.
• Select one of the two color palettes by a long press of the MODE button (8).
• Activate the quick menu by briefly pressing the MENU button (7) to adjust the
brightness and contrast of the display (see the Quick Menu Functions section
of the full version manual for details).
• Upon completion of use turn the device off by a long press of the ON button (9).
5
ENGLISH
Crosshair
Display of attachment
15
17
16
Close
14
19
18
Open