Electrical - Water Ace R520C-T7-01 Manual Del Usuario

Sistema de tanque/bomba de chorro convertible
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical

Disconnect power before working on pump, motor, pressure switch, or wiring.
Never wire a 115 volt motor to a 230 volt line.
CHECK VOLTAGE SETTING.
Turn off power to the pump!
1.
2. Determine if the circuit for the pump is 115 or
230 volts.
3. A qualified person must install electrical wiring.
4. The voltage switch is factory set to 115 volts. If you
have 115 volt service, do not change the selection.
1/2 HP motors are preset at the factory for 115 volts.
5. To change the voltage (if necessary), remove the
motor capacitor cover and slide the switch fully to
the correct voltage.
6. Reinstall the cover.
Do Not Turn On Power Yet!
Motor
Capacitor
Cover
Pressure
Switch
(Cover Removed)
Ground Wire
Connection
Figure 8: Connect power supply wires to pressure
switch as shown.
CONNECT POWER SUPPLY WIRING
TO PRESSURE SWITCH
1. Remove the pressure switch cover.
2. Attach power and ground wires to the pressure
switch as indicated.
3. Reinstall the cover.
Do Not Turn On Power Yet!
Power
Supply
Connections
Figure 9A: Remove cover from capacitor box to
reach voltage change slide switch.
Figure 9B: Pump is shipped from factory set for
115-volt operation (above).To change to 230-volt
operation, slide switch to display '230' (below).
Figure 9C: Slide switch set for 230-volt operation.
7
5982 0409

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido