17. If working from Zettler relay 2, install the terminal ring
end of the new assembled 10 AWG wire (U, Figure
15a-b) onto the top of light switch 2 by using the screw
that was removed in Step 12. If working from Zettler
relay 1, install wire onto light switch 3. If working from
Zettler relay 3, install wire onto light switch 6 for a
6-light unit or light switch 4 for a 4-light unit. Make sure
screw is tightened down on the ring terminal.
15a
Light Switch 5
Light Switch 3
Light Switch 1
15b
Light Switch
Connection Detail
18. Loosen the screw on AC post 2 of 725 light relay 2 and
connect the fork terminal onto the post from the wire
(V, Figure 16a) that was installed onto light switch
in Step 17. Tighten down the screw onto the fork
terminal.
12
Light Switch 4
Light Switch 6
Light Switch 2
U
Light Switch 2
19. On Zettler light relay 2 disconnect the existing 16 AWG
black wire (W, Figure 16a-b) from the DC ground
spade. This wire should be leading from the divider
panel of the component block. On Zettler relay 1 or
3 disconnect the 16 AWG black wire from the same
spade.
16a
U
16b
Zettler Relay 2
Zettler Relay
Disconnection Detail
W
Zettler Relay 2
725 Relay 2
V
W
www.allmand.com