Allmand 725 Instrucciones De Instalación página 8

Ocultar thumbs Ver también para 725:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2
3. Look in to the component box to determine a
convenient back side location near the existing Zettler
light relays (C, Figure 3a) to install the two 725 light
relays (D, Figure 2, Ref. 1) from the kit contents or
use the suggested layout for installing the relays as
shown in Figure 3a. Using the slots as guides on
the 725 relays, drill 1/8" holes into the back side of
the component box. Install the new relays in the box
by securing them with the #8 x 5/8 hex washer head
screws (Ref. 9). Add RTV sealant to the screws if
necessary. Install the relays with the DC posts facing
up and the AC posts down for more accessible wire
connections.
4. The DC and AC detail configurations of the new 725
light relays and the existing Zettler light relays are
shown in Figures 3b and 3c. Refer to these figures for
relay disconnection and connection points.
3a
Zettler Relay 1
Zettler Relay 2
Zettler Relay 3
725 Relay 1
725 Relay 1
Suggested 725 Relay Layout
8
B
5. Note: The 725 light relays shown in these installation
6. On Zettler light relay 2 disconnect the existing 12 AWG
D
C
3b
DC Post 1
725 Relay Detail
3c
DC Power Spade
AC Light Switch Spade
AC Distribution
Block Spade
Zettler Relay Detail
instruction figures are for replacing damaged Zettler
light relay 2 on a Maxi-Lite II 6-light unit. Zettler light
relay 1 and 3 replacement on a Maxi-Lite II 6-light 3
phase unit and Zettler light relay 3 replacement on
a Maxi-Lite II 4-light 3 phase unit will be similar in
installation. The differences will be mentioned in the
instructions and not shown.
wire (E, Figure 4a-b) from the AC distribution block
spade. This wire should be leading from distribution
block 2. On Zettler relay 1 of a Maxi-Lite II 6-light unit
disconnect the wire leading from distribution block 1
from the same spade. On Zettler relay 3 of a Maxi-Lite
II 6-light or 4 light unit disconnect the wire leading from
distribution block 3 from the same spade.
DC Post 2
AC Post 1
AC Post 2
DC Ground Spade
www.allmand.com