11. Loosen the screw on AC post 2 of 725 light relay 2 and
connect the fork terminal on the wire (J, Figure 8a-b)
that is leading from either light switch 2 or 4 into the
post. Tighten down the screw onto the fork terminal.
12. On Zettler light relay 2 disconnect the existing 16 AWG
black wire (K, Figure 8a-b) from the DC ground spade.
This wire should be leading from the divider panel of
the component block. On Zettler relay 1 disconnect
the 16 AWG black wire from the same spade.
8a
K
8b
Zettler Relay 2
K
Relay Connection
and Disconnection Detail
13. Cut off and discard the female spade terminal from
the wire that was connected to the Zettler relay. Strip
off the appropriate amount of wire insulation and install
wire (L, Figure 9a-b) into a 3 pin lever lock (M, Figure
9a-b, Ref. 11) from the kit contents.
Zettler Relay 2
725 Relay
J
725 Relay
J
9a
M
9b
3 Pin Lever
Lock Connection Detail
14. From the kit contents, locate and select the black
16 AWG wire (N, Figure 10, Ref. 2). Cut the black
16 AWG wire in half. Keep one half of the wire, and
discard the other half of the wire. Strip the ends of the
cut wire, and crimp a blue fork terminal (O, Figure 10,
Ref. 9) on one of the ends.
10
N
M
O