AL-KO C05-4230 Manual Del Usuario página 17

Ocultar thumbs Ver también para C05-4230:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
Troubleshooting
Errors that occur
The rechargeable battery
has been removed from
the charging unit and is not
charged.
ADVICE
NOTE: How to determine the charge status is described in the instructions for use of the
B05-3640 rechargeable battery (see sections "Determining the charge status of the recharge-
able battery" and "Charge status displays on the rechargeable battery").
ADVICE
NOTE: If you encounter any malfunctions that are not listed in this table or that you cannot rectify
yourself, please contact the AL-KO service centre.
441633_c
Displays
Possible cause
The plug contacts of
the rechargeable bat-
tery or charging unit
are soiled.
The rechargeable bat-
tery or charging unit is
faulty.
The LED on
The rechargeable bat-
the charging
tery or charging unit is
unit flashes
too hot.
red.
The LED on
No mains voltage.
the charging
unit is not ac-
tive.
The red LED
There is a fault on the
on the rech-
rechargeable battery
argeable bat-
or on the charging unit
tery lights af-
(see above causes).
ter pressing
the pushbut-
ton.
Solution
Disconnect the power plug
and clean the plug contacts
with a dry cloth. If the fault
reoccurs, contact an AL-KO
service centre.
Replace the rechargeable
battery. Only use original ac-
cessories from AL-KO.
Disconnect the power plug
and let the rechargeable bat-
tery and charging unit cool
down. Keep the ventilation
slots of the charging unit
clear.
Insert the power plug or
check that mains voltage is
present.
See above measures.
17

Publicidad

Tabla de contenido
loading

Tabla de contenido