Connect the two conductors from the control or mechanical switch to either pair of input terminals on the bottom of the alarm unit (see Figure B). The control
switch operates on low voltage to reduce shock hazards. The second input may be used to connect a second switch or dry contacts from another device.
OPERATION AND TESTING
Check and test your installation by lifting the float manually (see Figure E or G). The alarm unit will indicate an alarm condition by beeping and lighting a red
LED above "Input 1". The alarm may be silenced for 24 hours* by briefly pressing the Silence button. Once silenced, the LED changes to a flashing state and the
audible horn will not sound. Once the high water condition is remedied, the alarm should be reset by holding the Silence button for 2 seconds. Zoeller Company
cannot be responsible for damages caused by faulty or negligent installation of this device. We respectfully suggest you engage the services of a qualified,
licensed electrician or service person. Hold the Silence button for more than 4 seconds to test once per week to verify proper operation.
During a power outage, the APak
®
installed, the alarm will sound every 5 seconds.
*24 hours is the default setting. This and other settings may be changed from Z Control
Item
1
2
3
4
CLAMP DETAIL
7" (17.8 cm)
TETHER LENGTH
FOR ALARM FLOAT
Figure F
SK1301F
CONTROL/MECHANICAL SWITCH WIRING
For units without internet connectivity, see the standard APak
will beep every 30 seconds until the power is restored. If a high water alarm occurs during power outage with batteries
Description
Clamp, #36 worm-SS
Supply, power (service part)
Switch, vertical reed (service part)
Switch, mechanical float
© Copyright 2018 Zoeller
7"
Figure G
10-4011, 10-4012.
®
Cloud.
®
Models
10-4013-A
3/16
Qty
thru
Current
1
001766
1
154018
1
154033
1
N/A
Co. All rights reserved.
®
3
CLAMP
DETAIL
ALARM
LEVEL
SK1301G
10-4014-A
3/16
thru
Current
001766
154018
N/A
10-2060
SK3113

Publicidad

loading

Este manual también es adecuado para:

Z control apak 10-4014-a