Operation
Operation As A Rooftop
Reservoir Booster System
1. Open a faucet near the pump.
2. Plug the pump into a grounded, 3-wire outlet. The
pump should start.
3. Let the pump run until all air is out of the system and
the faucet is running solid water.
4. When the faucet is running solid water, close the
faucet. The pump should run until the water pressure
rises to the pressure switch's OFF setting. The pump
should then stop.
NOTE: Check the system by running it through one
complete pumping cycle to make sure it works. To do
this, open a faucet and bleed off pressure until the
pump starts. Close the faucet, and when the pressure
in the system has built up again, the pump should
stop.
Congratulations on a successful installation.
If you were unsuccessful, please refer to the
Troubleshooting section (Page 8) or call our customer
service technical staff at 1-262-728-5551.
115V
Black
Circuit
Breaker
Box
Hot
Black
Float Val v e
Cistern
Foot Valve
Float Switch :
Up = On
Down = Off
Wiring Connections – Schematic
Hot
Circuit
Cistern Float
Breaker
Switch
Box
Neutral
Figure 8 – Tinaco Application.
Tinaco
Float Switch :
Up = Off
Down = On
Pump
City Wa ter Inlet
Hot – Brown
Pum p
Tinaco
Float Switch
Neutral – Black
Neutral
115V
Booster Pump
Float Switch:
Circuit
Up = On
Breaker
Down = Off
Box
Hot
Check
Valve
Pump
Cistern Pump
Float Valve
Cistern
Foot Valve
Float Switch:
Up = On
Down = Off
Wiring Connections – Schematic
Booster Pump
Float Switch
(In Tinaco)
Cistern Float
Circuit
Breaker
(In Cistern)
Box
Neutral
Figure 9 – Cistern/Tinaco Booster Application.
Pump-Up
Float Switch:
Up = Off
Down = On
Tinaco
Pressure
Tank
Check
Pump
Pump
Valve
Pressure Booster Pump
City Water Inlet
Pressure
Booster
Pump
Hot
Hot – Brown
(In Tinaco)
Switch
Cistern
Pump
Float Switch
Neutral – Black
7
Pump-Up
4581 1005