1.2

General safety instructions

H Notices for the target group
These installation instructions are intended for
qualified persons who are skilled in dealing with
refrigeration engineering and HVAC technology and
also electrical systems. All system-relevant
instructions must be observed. Failure to comply with
instructions may result in material damage and
personal injury, including danger to life.
▶ Before carrying out the installation, read the
installation instructions of all system elements.
▶ Observe the safety instructions and warnings.
▶ Follow national and regional regulations, technical
regulations and guidelines.
▶ Record all work carried out.
H General dangers posed by the refrigerant
▶ This appliance is filled with refrigerant R32. If the
refrigerant gas gets into contact with fire, it may
generate toxic gas.
▶ Thoroughly ventilate the room if refrigerant leaks
during the installation.
▶ Check the tightness of the system following the
installation.
▶ Do not to let any other substance than the specified
refrigerant (R32) into the refrigerant cycle.
H Safety of electrical devices for domestic use
and similar purposes
The following requirements apply in accordance with
EN 60335-1 in order to prevent hazards from
occurring when using electrical appliances:
"This appliance can be used by children of 8 years and
older, as well as by people with reduced physical,
sensory or mental capabilities or lacking in experience
and knowledge, if they are supervised and have been
given instruction in the safe use of the appliance and
understand the resulting dangers. Children shall not
play with the appliance. Cleaning and user
maintenance must not be performed by children
without supervision."
"If the power cable is damaged, it must be replaced by
the manufacturer, its customer service department or
a similarly qualified person, so that risks are avoided."
H Handover to the user
When handing over the air conditioning system,
explain the operation and operating conditions to the
operator.
▶ Explain operation – with particular emphasis on all
safety-related actions.
Climate 5000 MS – 6721830160 (2020/12)
▶ Highlight the following points in particular:
– Point out that modifications or repairs may be
carried out only by an approved contractor.
– To ensure safe and environmentally compatible
operation, an annual inspection, and also
cleaning and maintenance if required, must be
carried out.
▶ Point out the possible consequences (personal
injury and possible danger to life or material
damage) of not carrying out inspection, cleaning
and maintenance correctly, or omitting it
altogether.
▶ Hand over the installation and operating
instructions to the user for safekeeping.
1.3

Notices regarding these instructions

The figures are shown together at the end of these instructions. The text
contains references to the figures.
Depending on the model, the products may be different to those shown
in these instructions.
2

Product Information

2.1

Declaration of conformity

The design and operating characteristics of this product comply with the
European and national requirements.
The CE marking declares that the product complies with all the
applicable EU legislation, which is stipulated by attaching this
marking.
The complete text of the Declaration of Conformity is available on the
Internet: worcester-bosch.co.uk.
2.2

Type overview

Depending on the outdoor unit, varying numbers of indoor units can be
connected:
Unit type
Climate 5000 MS ...
Connections
14 OUE
2 × 6.35 mm (1/4")
18 OUE
2 × 9.53 mm (3/8")
21 OUE
3 × 6.35 mm (1/4")
27 OUE
3 × 9.53 mm (3/8")
28 OUE
4 × 6.35 mm (1/4")
36 OUE
3 × 9.53 mm (3/8")
1 × 12.7 mm (1/2")
42 OUE
5 × 6.35 mm (1/4")
4 × 9.53 mm (3/8")
1 × 12.7 mm (1/2")
Table 2 Outdoor unit appliance types
Product Information
Quantity
Indoor units (max.)
2
3
4
5