IITEMS REQUIRED
(Purchase separately)
• Phillips screwdriver
• Weatherproof silicone caulk
IMPORTaNT SaFETY INSTRUcTIONS
When using product, basic precautions should always be followed, including the following:
• Heed all warnings, including below warnings AND those included on product.
• Save these instructions and warnings.
• For outdoor use only.
• cULus LISTED for wet location.
• Your fixture is prewired and preassembled for easy installation.
WARNING
• Read and follow these instructions.
• Risk of fire/electric shock. If not qualified, consult an electrician.
• Disconnect power at fuse or circuit breaker before installing or servicing.
caUTION
• Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids
the warranty.
• Fixture should be installed by persons with experience in household wiring or by a
qualified electrician. The electrical system, and the method of electrically connecting
the fixture to it, must be in accordance with the National Electrical Code and local
building codes.
• Fixture designed for wall mount to a recessed junction box only. Install fixture to
junction box marked for use in wet locations.
FOR BEST RESUlTS
• Install patio light 7-10 feet above the ground.
• Do not mount fixture close to reflective
surfaces such as windows, white walls,
white surfaces and water.
• When installing two fixtures on one switch,
make sure the switch is rated for at least
a 1 A inductive load.
MOUNTING YOUR FIXTURE
NOTE: Do not mount within 2 feet of a highly reflective
exterior inside corner (Fig. 1).
Questions? /¿Preguntas ? 1-800-334-6871 ConsumerProducts@cooperlighting.com
PACKAGING CONTENTS/ CONTENIDO DEL PAQUETE
A. Light fixture
B. Mounting bracket
Accesorio
Soporte de montaje
E. (3) Wire nuts
(3) Conectores
de cable
1
2 ft.
2 ft.
2 ft.
C. (2) #6 and (2) #8 junction box screws
(use the size that fits your junction box)
(2) Tornillos #6 y (2) tornillos #8 para
montaje de la caja de conexión
(utilice el tamaño que mejor se
adecue a su caja de conexión)
F. Cap nut
Tuerca tapa
1. Turn off the power at the main fuse/breaker box.
2. Attach mounting bracket (B) to junction box with
two screws (C) provided (Fig. 2).
3. Screw the threaded mounting rod (D) into the
center of the mounting bracket (B) until the
threads are showing on the back side of the
mounting bracket (B) (Fig. 3).
WIRING YOUR FIXTURE
1. Turn off the power at the main fuse/breaker box.
2. Connect the black fixture wire to the black supply
wire (hot) using wire connector (E) (Fig. 4).
3. Connect the white fixture wire to the white supply
wire (neutral) using wire connector (E) (Fig. 4).
4. Connect the copper ground fixture wire to an
appropriate supply ground or a grounded
junction box.
NOTE: Be careful to connect the wires correctly.
Make sure no bare strands of wire extend from the
wire connector (E) provided or other approved wire
connectors (not provided).
5. Attach fixture to the threaded mounting rod (D).
6. Secure with cap nut (F) (Fig. 5).
7. Add silicone caulk around fixture to help maintain a
weather-resistant seal.
calIFORNIa TITlE 24
1
Instruction Manual / Instrucciones
D. Threaded mounting rod
Varilla roscada para
montaje
2
C
C
B
3
B
D
4
A
5
A
F
Junction box
Junction box
Junction box
D
E
E
Junction box
D

Publicidad

loading

Resumen de contenidos para Cooper Lighting ALL-PRO FE0650LPC

  • Página 1 Instruction Manual / Instrucciones Questions? /¿Preguntas ? 1-800-334-6871 ConsumerProducts@cooperlighting.com PACKAGING CONTENTS/ CONTENIDO DEL PAQUETE A. Light fixture B. Mounting bracket C. (2) #6 and (2) #8 junction box screws D. Threaded mounting rod (use the size that fits your junction box) Accesorio Soporte de montaje Varilla roscada para...
  • Página 2 WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. blancas, superficies blancas y agua. Cooper Lighting Solutions (“CLS”) warrants to customers that, for a period of two years from • Cuando instale dos portalámparas en un único interruptor, asegúrese de que el interruptor the date of purchase, CLS’...
  • Página 3 SEAN IMPLÍCITAS, EXPLÍCITAS O ESTATUTARIAS, INCLUIDAS, ENTRE OTRAS, LAS GARANTÍAS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN PARTICULAR. Cooper Lighting Solutions (“CLS”) garantiza a sus clientes que los productos de CLS no presentarán defectos en los materiales y en la fabricación durante un período de dos años desde la fecha de compra.

Este manual también es adecuado para:

Fe0650lpcwAll-pro fe0650lpcw