LASER
Do not stare into beam. Do not point laser light at other persons.
Do not view directly into beam with optical instruments (binocular,
telescope).
Do not point laser at reflective surfaces,
Avoid exposure to laser radiation. Laser may emit hazardous
radiation.
Do not replace the installed laser with a different type.
Any repairs must only be carried out by the authorized service
agent.
SPECIFIED CONDITIONS OF USE
The mitre saw can be used for sawing solid wood, bonded wood,
glued veneer, materials similar to wood, and plastics.
Stock having a round or irregular cross section (such as firewood) must
not be cut, as it can not be securely held during cutting. When sawing
thin stock layed on edge, a suitable auxilary fence must be used for
firm support.

RESIDUAL RISK

GB
Even when the product is used as prescribed, it is still impossible to
completely eliminate certain residual risk factors. The following ha-
zards may arise in use and the operator should pay special attention
to avoid the following:
• Impairment of hearing, restrict exposure and wear appropriate
hearing protection.
• Measures that can be taken by operator to possibly reduce the
effects of vibration and limit the amount of exposure.
• Health hazards caused by breathing dust developed when
sawing wood, wear a mask if necessary.

MAINS CONNECTION

Connect only to single-phase AC system voltage as indicated on the rating
plate. It is also possible to connect to sockets without an earthing contact
as the design conforms to safety class II.
Appliances used at many different locations including wet room and
open air must be connected via a residual current device (FI, RCD, PRCD)
of 30mA or less.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine. Always lead
the cable away behind you.
Before use check machine, cable, and plug for any damages or material
fatigue. Repairs should only be carried out by authorised Service Agents.
English
26
26
MAINTENANCE
Always disconnect the plug from the socket before carrying out any
work on the machine.
If the replacement of the supply cord is necessary, this has to be
done by the manufacturer or his agent in order to avoid a safety
hazard.
If the supply cord of this power tool is damaged, it must be
replaced by a specially prepared cord available through the service
organization.
Be sure to disconnect the tool from the power supply before
attaching or removing the saw blade.
Replace the table insert when worn
Clean tool and guarding system with dry cloth.
The ventilation slots of the machine must be kept clear at all times.
Use only Milwaukee accessories and Milwaukee spare parts. Should
components need to be replaced which have not been described,
please contact one of our Milwaukee service agents (see our list of
guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please state
the Article No. as well as the machine type printed on the label
and order the drawing at your local service agents or directly at:
Techtronic Industries GmbH, Max-Eyth-Straße 10, 71364 Winnen-
den, Germany.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product described
under "Technical Data" fulfills all the relevant provisions of the
directives
2011/65/EU (RoHS)
2006/42/EC
2014/30/EU
and the following harmonized standards have been used.
EN 62841-1:2015
EN IEC 62841-3-9:2020+A11:2020
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 55014-1:2017+A11:2020
EN 55014-2:2015
EN IEC 63000:2018
Winnenden, 2021-07-28
Alexander Krug / Managing Director
Authorized to compile the technical file
Techtronic Industries GmbH
Max-Eyth-Straße 10, 71364 Winnenden, Germany