Residual Risk; Mains Connection; English - Milwaukee MS 305 DB Manual Original

Ocultar thumbs Ver también para MS 305 DB:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
WARNING Read all safety warnings and all instruc-
tions. Failure to follow the warnings and instructions may result in
electric shock, re and/or serious injury.
Save all warnings and instructions for future reference.
MITRESAW SAFETY WARNINGS
Wear ear protectors. Exposure to noise can cause hearing loss.
Always wear goggles when using the machine. It is recommended
to wear gloves, sturdy non slipping shoes and apron.
Wear gloves!
The dust produced when using this tool may be harmful to health.
Do not inhale the dust. Use a dust absorption system and wear a
suitable dust protection mask. Remove deposited dust thoroughly,
e.g. with a vacuum cleaner.
Connect the saw to a dust-collecting device when sawing wood.
Before using the tool please read the instructions. If possible have
the tool demonstrated.
Ensure that the machine is always stable and secure (e.g. xed to
a bench)
Keep the oor area free of loose material e.g. chips and cut-o s.
Do not use saw blades not corresponding to the key data given in
these instructions for use.
Do not use saw blades which are damaged or deformed
Do not use saw blades made of high-speed steel.
Only use tools that meet standard EN 847-1.
It is necessary to select a saw blade which is suitable for the
material being cut.
Only use saw blades which have been properly sharpened. It is
essential to adhere to the maximum speed speci ed on the saw
blade.
Do not use any anges other than those supplied or indicated in the
instruction manual to secure the saw blade.
Transport and store the tools in a suitable receptacle;
Never use the mitre saw to cut materials other than those speci ed
in the instruction manual.
Only use the saw with guards in good working order and properly
maintained, and in position.
Refrain from removing any cut-o s or other parts of the workpiece
from the cutting area whilst the machine is running and the saw
head is not in the rest position.
Never reach into the danger area of the machine when it is running.
Always use the protective shields on the machine.
Any faults with the machine, including any related to the safeguard
or the saw blades, must be reported to the persons in charge of
safety as soon as the faults are discovered.
Do not clamp the protective swing guard.
Long workpieces must be adequately supported.
The handle lock must always be engaged when transporting the
mitre saw.
Do not replace the LED with a di erent type. Any repairs must only
be carried out by the authorized service agent.
SPECIFIED CONDITIONS OF USE
The mitre saw can be used for sawing solid wood, bonded wood,
glued veneer, materials similar to wood, and plastics.
Stock having a round or irregular cross section (such as rewood)
must not be cut, as it can not be securely held during cutting. When
sawing thin stock layed on edge, a suitable auxilary fence must be
used for rm support.

RESIDUAL RISK

Even when the product is used as prescribed, it is still impossible
to completely eliminate certain residual risk factors. The following
hazards may arise in use and the operator should pay special
attention to avoid the following:
• Impairment of hearing, restrict exposure and wear appropriate
hearing protection.
• Measures that can be taken by operator to possibly reduce the
e ects of vibration and limit the amount of exposure.
Health hazards caused by breathing dust developed when sawing
wood, wear a mask if necessary.

MAINS CONNECTION

Connect only to single-phase AC system voltage as indicated on
the rating plate. It is also possible to connect to sockets without an
earthing contact as the design conforms to safety class II.
Appliances used at many di erent locations including wet room
and open air must be connected via a residual current device (FI,
RCD, PRCD) of 30mA or less.
Always disconnect the plug from the socket before carrying out any
work on the machine.
Only plug-in when machine is switched o .
Keep mains lead clear from working range of the machine. Always
lead the cable away behind you.
Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
MAINTENANCE
If the supply cord of this power tool is damaged, it must be
replaced by a specially prepared cord available through the service
organization.
Be sure to disconnect the tool from the power supply before
attaching or removing the saw blade.
Replace the table insert when worn
Clean tool and guarding system with dry cloth.
The ventilation slots of the machine must be kept clear at all times.
Use only Milwaukee accessories and Milwaukee spare parts. Should
components need to be replaced which have not been described,
please contact one of our Milwaukee service agents (see our list of
guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the Article No. as well as the machine type printed on the
label and order the drawing at your local service agents or directly
at: Techtronic Industries GmbH, Max-Eyth-Straße 10, 71364 Win-
nenden, Germany.
GB

English

23

Publicidad

Tabla de contenido
loading

Tabla de contenido