Timer for turning on the unit:
Press „TIMER" while the unit is in standby mode and set the desired time at which the unit shall
o
turn on by using the buttons „UP" and „DOWN" between 0 and 24 hours.
Select the required function (cooling, heating, dehumification) and set the required temperature.
o
o
When the set time has expired, the unit starts automatically.
If you press „POWER" before the time has expired, the time programming is deleted and the
o
unit switches back on.
•
Timer for turning off the unit:
Press „TIMER" while the unit is operating and set the desired time at which the unit shall turn
o
off by using the buttons „UP" and „DOWN" between 0 and 24 hours.
After the flashing of the number of hours on the LED has stopped, you can select the required
o
function (cooling, heating, dehumification) and the required temperature.
o
When the set time has expired, the unit turns off automatically.
If you press „POWER" before the time has expired, the time programming is deleted and the
o
unit turns off.
•
Operation mode dehumidifying:
Close all doors and windows during this operation mode to ensure no additional humidity will
o
enter the room. The exhaust hose will not be required in this mode.
Press „MODE" until the according indicating light lights up. The display shows „dH".
o
The ventilation speed is set as „LOW" automatically.
o
•
Water tank:
When the water tank is full the codes „E2" in operation modes dehumidifying and cooling and
o
„E4" in operation mode heating will be shown at the LED display. The compressor stops working.
Remove the plug from the drainage hole and let the water drain with a drain hose. (see pic.3).
Close the drainage hole with the plug. The corresponding code will disappear and the unit will
operate again.
•
Automatic evaporation and drainage of condensed water:
The machine can automatically evaporate condensing water and drain out of the exhaust hose.
o
Please ensure that the plug is installed properly during operation mode cooling. In operation
modes heating and dehumidifying the plug needs tob e removed. Install a drain hose to drain
the water (continuous drainage).
Additional notes cooling mode
✓ We recommend starting the unit early in the morning on warm days to get a cool room.
✓ This unit has a self-evaporation function for condensation water, so that it is normally not necessary to
empty the water tank in cooling mode. The drainage hose need not be connected. Please make sure
that the outlet is closed with the rubber cap during operation.
(This does not apply in the case of high air humidity. If the unit operates in cooling mode for a longer period and
especially at a time of year with high air humidity, the condensation tank may be full. Error code "E2" will remind you
to empty the water. In such a case, empty the water tank via the condensation water outlet. If continuous high air
humidity is likely, it is recommended to drain the condensation continuously via the drainage hose.)
COOLING IN INDOOR OPERATION
The TRANSFORM unit stands in the room to be cooled.
Connect the air hose and the air outlet grid to the TRANSFORM unit as displayed in the illustration; the air
hose connection piece and air outlet grid need to be exchanged.
Pic. 3