Maintenance; Light Bulb Replacement - Dimplex DCF44GS Manual Del Propietário

Ocultar thumbs Ver también para DCF44GS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance

Light Bulb Replacement

CAUTION: Allow at least five
(5) minutes for light bulbs to cool
before touching bulbs to avoid
accidental burning of skin.
!
NOTE: Light bulbs need to be
replaced when you notice a dark
section of the flame or when the
clarity and detail of the log ember
bed exterior disappears. There
are three (3) bulbs under the log
set, which generate the flames
and embers, and two (2) bulbs
above the log that illuminate the
log exterior.
Lower Light Bulb Requirements
Quantity of three (3) clear
chandelier or candelabra bulbs
with an E-12 (small) socket base,
60 Watt rating. Example: GE
60BC or Philips 60 CTC.
Do not exceed 60 Watts per
bulb
Helpful Hints: It is a good idea to
replace all light bulbs at one time
if they are close to the end of their
rated life. Group replacement will
reduce the number of times you
need to open the unit to replace
light bulbs. Care must be taken
when removing the logset as the
logset contains LED's and wires.
To access the lower light bulb
area (Figure 5):
1.
Remove front glass assembly.
2.
Pull the front edge of the
plastic ember bed or plastic
grate up and forward until the
rear tab releases from the
ledge located at the bottom of
the partially reflective glass.
Figure 5
upper Bulbs
Lower Bulbs
Front
Glass
Log Set
!
IMPORTANT: only handle the
logset by the emberbed.
!
NOTE: Logset fits tightly
into firebox, some force may be
necessary to remove.
3.
Set logset in front of fireplace.
4.
Disconnect the logset LED
wire harness from unit.
5.
unscrew bulbs counter
clockwise.
6.
Insert new bulbs.
7.
Reconnect the logset LED
LED
Wire Harness
13