Resumen de contenidos para SilverStone FORTRESS Serie

  • Página 1 FORTRESS SERIES FT04 MANUAL...
  • Página 2: Tabla De Contenido

    Installation and system optimization guide: The following manual and guides were carefully prepared by the SilverStone engineering team to help you maximize the potential of your SilverStone product. Please keep this manual for future reference when upgrading or performing maintenance on your system. A copy of this manual can also be downloaded from our website at: http://www.silverstonetek.com...
  • Página 3 FT04 FORTRESS SERIES Setting the thermodynamic benchmark Aluminum door and top panel, steel body steel body SSI-EEB, SSI-CEB, Extended ATX, ATX, Micro-ATX Model No. SST-FT04B-W (black + window) SST-FT04S-W (silver + window) 5.25" x 2 Exposed 3.5“ x 1 (transfer bracket,未定案) Internal 3.5"...
  • Página 4 Secure 2.5” HDD Secure optical drives Secure VGA holder and claw Secure PSU, 12025 fan, motherboard and 3.5” HDD Motherboard standoff Secure 12025 fan VGA supporter holder VGA supporter claw Standoff screw Cable management...
  • Página 6: Installation Guide

    lnstallation Guide Loosen two screws from both left Отвинтите по два винта, крепящих and right side panels to remove левую и правую боковых панели, them. и снимите панели. Lösen Sie die beiden Schrauben 取下左右側板各兩顆螺絲,卸下側板。 an den linken und rechten Seitenwänden, nehmen Sie die Seitenwände ab.
  • Página 7 lnstallation Guide Loosen three screws holding the Отвинтите три винта, крепящих motherboard tray to remove it. кронштейн материнской платы, и снимите его. Lösen Sie die drei Schrauben, welche 取下主機板托盤3顆螺絲,將主機板托盤抽出。 die Motherboard- Halterung fixieren, nehmen Sie die Halterung ab. Desserrez les trois vis tenant le plateau 取下主机板托盘3颗螺丝,将主机板托盘抽出。...
  • Página 8 lnstallation Guide Remove 3.5” drive cage. Извлеките кронштейн для 3,5-дюймовых жестких дисков. Nehmen Sie die 3,5 移除3.5”主硬碟架。 Zoll-Laufwerkhalterung heraus. Retirez le casier des lecteurs 3.5”. 移除3.5”主硬盘架。 3.5インチドライブケージを取り外します。 Quite la carcasa para dispositivos de 3,5” Rimuovere il supporto hard 3.5” 드라이브 케이지를 제거합니다. drive da 3,5”...
  • Página 9 lnstallation Guide Install 2.5” drive into the bottom of Установите 2,5-дюймовый жесткий диск в the chassis and secure with screws. нижнюю часть корпуса и закрепите его винтами. Installieren Sie das 2,5 Zoll-Laufwerk 將2.5”硬碟裝入機殼底部,並鎖上螺絲。 im unteren Teil des Gehäuses; anschließend mit Schrauben fixieren. Installez le lecteur 2.5”...
  • Página 10 lnstallation Guide Install motherboard rear I/O plate Установите в корпус заднюю панель into the chassis. ввода-вывода материнской платы. Installieren Sie das hintere 將I/O彈片裝上機殼。 I/O-Blech im Gehäuse. Installez la plaque arrière de la carte 将I/O弹片装上机壳。 mère dans le boîtier. Instale la placa trasera de E/S de la ケース内にマザーボード後部...
  • Página 11 lnstallation Guide Reinstall the assembled motherboard Установите кронштейн с материнской tray back into the chassis. If you have платой в сборе в корпус. Если был either the ATX12V 4pin or EPS 8pin подключен 4-контактный разъем кабеля cables connected, please make sure ATX 12 В...
  • Página 12 lnstallation Guide We recommend that you start cable На этом этапе рекомендуется начать manage now and connect cables прокладку кабелей и подсоединить such as the ATX 24pin, front I/O кабели, например кабель ATX с connectors, and any other connectors 24-контактным разъемом, разъемы from front panel devices.
  • Página 13 lnstallation Guide Route all power supply cables to the Проложите все кабели питания через opening on the left of the power отверстие слева от блока питания. supply. Verlegen Sie sämtliche Netzteilkabel 請將所有電源線穿過電源左邊的開孔。 durch die Öffnung links vom Netzteil. Faîtes passer tous les câbles de 请将所有电源线穿过电源左边的开孔。...
  • Página 14 lnstallation Guide Install hard drive cage back into the 1Установите кронштейн для жестких case with cables routed. дисков на место в корпус с проложенными кабелями. Bauen Sie die Laufwerkhalterung 將3.5”主硬碟架裝回機殼, wieder das Gehäuse ein. Achten 同時請注意理線。 Sie darauf, die Kabel sauber zu verlegen.
  • Página 15 lnstallation Guide Connect all cables for 5.25”, 3.5”, Подсоедините все кабели 5,25-дюймовых, and 2.5” drives as needed. 3,5-дюймовых и 2,5-дюймовых устройств соответствующим образом. Schließen Sie sämtliche Kabel für 先連接上所有磁碟需要用到的線材 verwendete 5,25-, 3,5- und (包含5.25”、3.5”以及 2.5”) 2,5-Zoll-Laufwerke an. Branchez tous les câbles pour les 先连接上所有磁盘需要用到的线材...
  • Página 16 lnstallation Guide Insert 3.5” hard drive into the lower Установите 3,5-дюймовый жесткий hard drive cage диск в нижний отсек для жестких дисков Setzen Sie eine 3,5-Zoll-Festplatte 額外的3.5”硬碟,請安裝於底部 in den unteren Festplattenkäfig ein 硬碟架。 Insérez le lecteur 3,5" dans la cage 额外的3.5”硬盘,请安装于底部...
  • Página 17 lnstallation Guide Reinstall both left and right side Для завершения установки установите на panel to complete installation. место левую и правую боковые панели. Installieren Sie zum Abschluss 裝回左右側板,完成組裝。 der Installation die linke und rechte Seitenwand wieder. Réinstallez les deux panneaux latéraux 装回左右侧板,完成组装。...
  • Página 18: Connector Definition

    Connector definition (1) Front panel connector installation Power switch and reset switch installation guide: Please refer to the motherboard manuals for the motherboard’s “Front Panel Connector” or “System Panel Connector” pin definition. Power switch and reset switch have no polarity, so they can be connected in any orientation. Ein-/Ausschalter und Rücksetztaste (Reset) installieren: Bitte suchen Sie in der Motherboard-Dokumentation nach der Pinbelegung der Anschlüsse des Frontbedienfeldes („Front Panel Connectors“...
  • Página 19 Connector definition Please refer to the motherboard manuals for the motherboard’s “Front Panel Connector ” or “System Panel Connector” pin definition.; the white/black wires are negative while other colors are positive wires. The Power LED wires are separate pins for compatibility with different motherboard pin definition so please make sure they are connected in the right polarity by referring to your motherboard manual.
  • Página 20: Front I/O Connector Guide

    Front I/O connector guide Below are the front I/O connectors pin definition, please also check your motherboard manual to cross reference with motherboard’s front I/O pin headers. Nachstehend finden Sie die Pinbelegung der vorderen E/A-Anschlüsse; bitte gleichen Sie zudem das Handbuch Ihres Motherboards mit den vorderen E/A-Pinzuweisungen ab.
  • Página 21: Component Size Limitations

    Component size limitations The FT04 can accommodate all standard size components and even some that are out of spec, please refer to the following guidelines for component selection and future upgrade considerations: (1) CPU Cooler limitation The height limit is 165mm and there is 13mm of clearance around the motherboard’s top edge. The clearance toward the front of the case is variable depending on how much you fill the hard drive cage.
  • Página 22 The Total length for power supply and optical drive: Power supply and the optical drive space in the FT04 share the same plane so the total limit is 439mm including possible room for cables. We recommend maximum size for power supply of up to 220mm such as the SilverStone’s ST1500. Maximum length limitation for PSU only is 285mm.
  • Página 23 Блок питания и привод оптических дисков в корпусе FT04 расположены на одной панели, поэтому их общая длина не может превышать 439 мм, включая возможное пространство для кабелей. Рекомендуется использовать блок питания длиной не более 220 мм, например модель SilverStone ST1500. Ограничение по длине для блока...
  • Página 24 Component size limitations (4) Memory height limitation There is 61mm of distance between the motherboard to the hard drive. If you use a memory similar to the one shown in the illustration, please remove the heatsink on it prior to installation. Zwischen Motherboard und Festplatte verbleiben 61 mm Platz.
  • Página 25 FT04 unterstützt maximal SSI-EEB (Extended-ATX-Motherboard) Hochmoderne Motherboards von SSI-CEB-Servern und -Arbeitsrechnern benötigen keine Löcher zur CPU-Kühlermontage am Motherboard-Einschub mehr. Die Kühler können nun direkt am Motherboard installiert werden. Dadurch haben wir die Unterstützung der Löcher zur SSI-CEB-CPU-Kühlermontage aufgegeben und stattdessen den Abstand am Motherboard-Einschub vergrößert;...
  • Página 26: Cpu And Graphic Card Supporter

    CPU and graphic card supporter A : CPU Cooler Supporter (1) First set the chassis on its side, make sure it is on a level surface. (2) The CPU supporter has already been installed in a commonly used position. You can loosen the screw in the middle to fully extend it. (3) If the supporter position is not optimal for your setup, remove two more screws on left and right side to move the supporter.
  • Página 27 A : CPU Cooler Supporter (1) Per prima cosa disporre il cabinet su un fianco, possibilmente su una superficie piana. (2) Il supporto per il dissipatore è già installato nel case in una posizione standard. Potete allentare le viti al centro per estenderlo completamente. (3) Se il supporto non si trova in posizione ottimale per il vostro setup, rimuovere due ulteriori viti a destra ed a sinistra per posizionare il supporto stesso.
  • Página 28: Optimal Thermal Performance Layout

    Optimal Thermal Performance Layout If you are installing a tower-style CPU cooler, we recommend that the CPU fan blows rearward to work with FT04’s overall airflow. Falls Sie einen tower-artigen CPU-Kühler installieren, empfehlen wir, den CPU-Lüfter die Luft nach hinten blasen zu lassen, damit er mit der gesamten Luftbewegung im FT04 zusammenarbeitet.
  • Página 29 如果您安装高阶显示卡,我们建议您选购风向为朝向Slot端的方式,这样安装上FT04时,风扇才会朝后吹,顺着FT04的气流配置 グラフィックカードを選ぶ際、ファン送風が後部スロット方向に排気を行うモデルを推奨します。これはFT04の中にスムーズで効率的な気流を生じ、 最大の冷却性能を実現します。 그래픽 카드를 선택할때, 슬롯 후면으로 팬의 바람 방향이 슬롯 후면 쪽으로 되어 있는 제품을 선택하기를 바랍니다. 이런 그래픽 카드를 선택해야, FT04의 공기흐름에 맞추어 최대의 냉각 성능을 발휘 할 수 있습니다. Optimal Thermal Performance Layout (3) Tips For Cable Management Please refer to the following diagrams A.
  • Página 30 Optimal Thermal Performance Layout (3) Tips For Cable Management B. The illustration explains which cables the openings are designed for cable placements, the illustration are based on most common motherboard designs. C.There is less than 10mm gap between the front edge of motherboard tray and left side panel. The gap between the top of the 5.25”...
  • Página 31 Optimal Thermal Performance Layout (3) Tips For Cable Management D. If multiple hard drives are installed, we recommend using CP06 to ease cable routing. D. Falls mehrere Festplatten installiert sind, empfehlen wir zur einfachen Kabelführung den CP06. D. Si plusieurs disques durs sont installés, nous vous recommandons d'utiliser CP06 pour un acheminement de câble facile.
  • Página 32: Upgrade And Maintenance

    SilverStone also has three models of 180mm fans for sale separately for replacement or upgrade SilverStone bietet zudem drei Modelle der 180 mm-Lüfter zum separaten Verkauf; mit diesen können Sie Ihr System aufrüsten oder alte Lüfter ersetzen SilverStone vend aussi trois modèles de ventilateur de 180mm pour le remplacement ou une amélioration.
  • Página 33 Конструкция корпуса FT04 обеспечивает избыточное давление воздуха и, таким образом, имеет эффективную конфигурацию, препятствующую скоплению пыли внутри корпуса. Небольшие частицы и волокна, содержащиеся в воздухе, со временем будут скапливаться на впускных фильтрах, а не на компонентах, находящихся внутри корпуса. Для поддержания превосходного охлаждения компонентов в корпусе FT04 в течение многих лет рекомендуется регулярно очищать все фильтры вентиляторов: раз...
  • Página 34 FT04 utilise des filtres à air plus fins qui offrent un taux de débit d’air plus élevé. Ils présentent la même capacité de filtrage mais ont un pourcentage de débit d’air accru de 65% à 90% par rapport à la génération précédente de filtres en nylon. Cependant, ces filtres plus fins ne sont pas aussi durables, veuillez donc prendre note des précautions de nettoyage suivantes lorsque vous les nettoyez.
  • Página 35 FT04採用更高通風性的超薄濾網,在保持相同的過濾能力之下,通風比例由之前尼龍紗網的65%提升到90%。但是這種濾網並不比以前的尼龍濾網堅固。以下是清潔上的注意事項: 清潔方法: 1.使用軟毛刷清理 濾網可以使用軟質毛刷進行清理。千萬不可以使用鋼刷,以免造成濾網損毀。建議在清理的時候戴口罩,以免吸入有害灰塵。 2.使用吸塵器清理 使用吸塵器清理是最方便的。如果你不方便將濾網拆下,請注意先固定住風扇之扇葉,再以吸塵器進行清理。避免吸塵器吸力過大,損壞風扇。 3.用水沖洗 通常來說,用水沖洗可將濾網清理的最乾淨。沖洗完,請將濾網放置在通風良好之陰暗處晾乾,避免陽光照射。嚴禁使用吹風機、烤箱或微波爐等方式對濾網進行加熱, 以免造成濾網損毀。如果您覺得濾網晾乾的時間過久,建議您可以準備一份濾網做替換。如果濾網尚未晾乾,在濕濕的狀態下裝回機殼使用,有可能會造成您電腦元件的短路以 及損壞,請務必避免。 注意事項: 因為纖維比較細,在使用過程須確保遠離魔鬼氈,以避免鈎黏住。溝黏住可能導致濾網的破損 添購濾網 如果您不慎遺失、人為損壞或只是想要多購買濾網備用。請與我們的經銷點聯絡進行購買。 請上SilverStone網站查詢各區域經銷 http://www.silverstonetek.com.tw/wheretobuy_all.php?area=tw T04采用更高通风性的超薄滤网,在保持相同的过滤能力之下,通风比例由之前尼龙纱网的65%提升到90%。但是这种滤网并不比以前的尼龙滤网坚固。以下是清洁上的注意事项: 清洁方法: 1.使用软毛刷清理 滤网可以使用软质毛刷进行清理。千万不可以使用钢刷,以免造成滤网损毁。建议在清理的时候戴口罩,以免吸入有害灰尘 2.使用吸尘器清理 使用吸尘器清理是最方便的。如果你不方便将滤网拆下,请注意先固定住风扇之扇叶,再以吸尘器进行清理。避免吸尘器吸力过大,损坏风扇。 3.用水冲洗 通常来说,用水冲洗可将滤网清理的最干净。冲洗完,请将滤网放置在通风良好之阴暗处晾干,避免阳光照射。严禁使用吹风机、烤箱或微波炉等方式对滤网进行加热,以 免造成滤网损毁。如果您觉得滤网晾干的时间过久,建议您可以准备一份滤网做替换。如果滤网尚未晾干,在湿湿的状态下装回机壳使用,有可能会造成您计算机组件的短路以 及损坏,请务必避免。 注意事项: 因为纤维比较细,在使用过程须确保远离魔鬼毡,以避免钩黏住。沟黏住可能导致滤网的破损 添购滤网 如果您不慎遗失、人为损坏或只是想要多购买滤网备用。请与我们的经销点联络进行购买。 请上SilverStone网站查询各区域经销 http://www.silverstonetek.com.tw/wheretobuy_all.php?area=tw FT04は、より高い気流比率を提供するより優れたエアフィルタが使用されています。これは、前世代のナイロン・フィルタと比較して65%から90%まで増加した気流比率で同一の フィルタリング能力を発揮します。しかし、これらの高性能フィルタは耐久性はさほどよくないので、お手入れの際は以下の点にご注意ください。 清掃方法: 1. ソフトブラシでの清掃 ファン・フィルタは、ソフトブラシを使って清掃できます。スチールブラシはフィルタに損傷を与えるので使わないでください。ファン・フィルタ清掃の際は、塵を吸い込ま ないよう、マスクの着用をお勧めいたします。 2.掃除機を使った清掃...
  • Página 36 Upgrade And Maintenance (2) ClearCMOS FT04 supports SST-CLEARCMOS installation on a designated part of the case, please see example below: Das FT04 unterstützt die SST-CLEARCMOS-Installation an einem dazu vorgesehenen Teil des Gehäuses; bitte halten Sie sich an das nachstehende Beispiel: Le FT04 est compatible avec l'installation du SST-CLEARCMOS dans une partie spéciale du boîtier, voici un exemple ci-dessous: La FT04 acepta la instalación de SST-CLEARCMOS en una parte dedicada a ello en la carcasa, por favor vea el ejemplo siguiente: FT04 supporta l’installazione, in una specifica zona del case, di SST-CLEARCMOS, come da esempio seguente:...
  • Página 37 CP05 e CP05-SAS possono essere acquistati separatamente se si vuole avere la funzione hot-swap. Prendere nota di quanto segue: A. Se avete bisogno di effettuare un hot-swap mentre è attivo il sistema operativo, dovete essere sicuri che il chipset di controllo del SATA (od il southbridge della scheda madre) siano dotati del supporto e dei driver specifici.
  • Página 38 A. Retirez les deux panneaux latéraux B. Ouvrez la porte d’accès frontal et enlevez le filtre du ventilateur. C. Desserrez les vis fixant le ventilateur pour le démonter D. Dévissez les vis qui tiennent le commutateur de vitesse du ventilateur, puis placez le commutateur à travers le trou du panneau frontal. (Note : Veuillez utiliser un petit tournevis pour ceci) E.
  • Página 39: Protect Your Computer

    Upgrade And Maintenance (5) Bottom hard drive removal guide Release the latch, and pull out hard drive using the strap. Lösen Sie den Riegel, ziehen Sie die Festplatte an der Schlaufe heraus. Libérez le verrou, puis sortez le disque dur en utilisant la sangle. Quite el seguro y tire del disco duro usando la correa Sbloccare la serratura ed estrarre il disco rigido usando la fascetta.
  • Página 46: Warranty Information

    Replacement product will be warranted for remainder of the warranty period or thirty days, whichever is longer. All products should be sent back to the place of purchase if it is within 30 days of purchase, after 30 days, customers need to initiate RMA procedure with SilverStone Technology in USA by first downloading the “USA RMA form for end-users”...
  • Página 48 Issue date: January, 2013 G11218050...