OPERATION
EXTENSION CORD SIZING
Only use grounded 3-prong extension cords marked for
outdoor use that are rated for the electrical load.
Minimum Gauge, Outdoor Rated
Total
Amperage
Up to 50 FT (15 M)
Up to 10A
12
10
Up to 15A
10
Up to 20A
8
Up to 30A
6
Up to 35A
TRANSPORTING
Weight hazard. ALWAYS have assistance when lifting
the generator.
• Allow the generator to cool a minimum of 30 minutes
before transporting.
• If operating on propane, turn the propane tank valve to
the fully closed position.
• Replace all protective covers on the generator control
panel.
• Keep the unit level during transport to minimize the
possibility of fuel leakage or, if possible, drain the fuel
or run the engine until the fuel tank is empty before
transport.
• The generator wheels are only intended for hand
transport. The wheels are not suitable for towing the
generator either on or off-road.
• Use the extendable handle for hand transport. Only use
the handle while the generator is OFF, stationary, and
resting on a horizontal surface. DO NOT use the handle
to lift the generator entirely off the ground, tow it, or up-
end it.
18 | Westinghouse Outdoor Power Equipment, LLC
Up to 100 FT (30 M)
1
8
8
1
6
6
6
CAUTION
Fire hazard. DO NOT up-end the generator or place it on
its side. Fuel or oil can leak and damage to the generator
may occur.
LIFTING HOOK
Only use the lifting hook to lift the unit or attach any load
restraints such as ropes or tie-down straps. DO NOT
attempt to lift or secure the generator by holding onto any
of its other components.
Before lifting the generator, inspect the bracket and make
sure it is securely fastened to the generator. DO NOT lift the
generator unless the lifting bracket is securely fastened.
1. Hook a chain or strap through the eye on the lifting hook
and make sure it is securely fastened.
2. Connect a suitable lifting device to the chain or strap.
Inspect chain and hook for any damaged links or any
defects that could cause failure. It is recommended to
use hooks with safety latches installed.
3. Lift the generator slightly to ensure it is lifting straight
and level.
CAUTION