4

Mounting

5

Electrical installation

8020358.14CS | SICK
Subject to change without notice
Mount sensors (sender and receiver) using suitable mounting brackets (see the SICK
range of accessories). Align the sender and receiver with each other.
NOTE
Swap the sender and receiver arrangement at every second through-beam photoelec‐
tric sensor and ensure that there is sufficient distance between the through-beam pho‐
toelectric sensors.
Sender (WS)
Receiver (WE)
Sender (WS)
Figure 1: Arrangement of several through-beam photoelectric sensors
Note the sensor's maximum permissible tightening torque of < 1,3 Nm.
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
Male connector connection: Note pin assignment
Cable: wire color
Only apply voltage/switch on the power supply once all electrical connections have
been established.
Explanations of the connection diagram
Alarm = alarm output
Health = alarm output
MF (pin 2 configuration) = external input, teach-in, switching signal
Q
/ C = switching output, IO-Link communication
L1
Test = test input
U
: 10 ... 30 V DC
B
(table 1
-
table
7):
4
MOUNTING
Receiver (WE)
Sender (WS)
Receiver (WE)
5