5. Installation

The activities described in this section must only
be executed by a qualified electrician.
T
T
ATTENTION
Damage to the device by improper
handling
Collisions and shocks may damage the device.
f Avoid collisions and impacts.
f Use a soft base to set aside the device.
5.1

Choice of location

The device is intended for permanent installation and for
indoor and outdoor use. A suitable location meets the fol-
lowing requirements:
„ Technical data and mains data are the same.
Î "4. Technical data"
„ Permissible ambient conditions are observed.
Î "5.2 Permissible ambient conditions"
„ The following minimum distances to other objects (e. g.
walls) must be complied with:
Clearance to the left and right: 300 mm
Clearance above: 300 mm
„ The device and the charging station are in sufficient
proximity to each other, depending on the charging
cable used.
10

5.2 Permissible ambient conditions

T
T
DANGER
Danger of injury and fire
If the device is operated in potentially explosive areas (ex
areas), explosive substances may be ignited by sparking
of device components.
f Do not use charging cable in potentially-explosive
atmospheres (e.g. at petroleum filling stations).
T
T
ATTENTION
Device damage due to unsuitable ambient conditions
Unsuitable ambient conditions can result in device dam-
age.
f Avoid direct sunlight.
f Protect the device from a direct water jet.
f Ensure adequate ventilation of the device.
Do not install in niches.
f Keep device away from heat sources.
f Avoid large temperature fluctuations.
Permissible ambient conditions
Ambient temperature
Average temperature over
24 hours
Altitude
Relative humidity
-25 ... +40 °C
< 35 °C
Max. 2,000 m above sea
level
max. 95 %
(non-condensing)