The white rotary encoder switch S2: Reduced charging
current with an external switching connection
Position(s)
0, 1, 2 and 3
16 A
4
13 A
5
10 A
6
8 A
7
6 A
8
0 a (charging paused)
9
Operating mode "External
Authorisation"
Operating mode "Permanent Authorisation"
f Set maximum charging current over the blue rotary
encoder switch S3 according to the maximum con-
nected load.
f Set the white rotary encoder switch S2 to position "0".
Operating mode "Permanent Authorisation with Load
Management"
Requirement:
An external potential-free switching contact is integrat-
9
ed into the house installation.
Î "5.6.2 Switching contact"
f Set maximum charging current over the blue rotary
encoder switch S3 according to the maximum con-
nected load.
f Set reduced charging current using the white rotary
encoder switch S2 as desired.
External
Switching
Contact
Opened
Charging with maximum charging
current (set with the blue rotary
encoder switch S3)
closed
Charging with reduced charging
current (set with the white rotary
encoder switch S2)
16
Reduced charging current
Meaning
Operating mode "External Authorisation"
Requirement:
9
An external potential-free switching contact is integrat-
ed into the house installation.
Î "5.6.2 Switching contact"
f Set maximum charging current over the blue rotary
encoder switch S3 according to the maximum con-
nected load.
f Set white rotary encoder switch S2 to position "9".
External
Switching
Contact
Opened
No charging possible
closed
Charging with maximum charging
current
6.2 Switching on the device
T
T
DANGER
Electric shock hazard when devices are damaged
If a damaged device is used people can be seriously
injured or killed through an electric shock.
f Do not use the device if it is damaged.
f Mark the damaged device to ensure that no one con-
tinues using it.
f Eliminate damage immediately.
f If necessary take the device out of service.