ECODESIGN REQUIREMENTS FOR heat pumps/air conditioners
Information requirements
A
Information to identify the model(s) to which the information relates : AC140KNPDEH / AC140KXADGH
B
Outdoor side heat exchanger of heat pump/air conditioners: [select which: air/water/brine] Air
C
Indoor side heat exchanger of heat pump/air conditioners: [select which: air/water/brine] Air
D
Indication if the heater is equipped with a supplementary heater: No
E
Type: [compressor driven vapour compression or sorption process] Compressor driven vapour compression
F
If applicable: driver of compressor: [electric motor or fuel driven, gaseous or liquid fuel, internal or external combustion engine] Electric motor
G
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons are optional.
Item
(H)
L
Rated cooling capacity
Declared cooing capacity for part load at given outdoor
O
-
Degradation co-efficient
Q
for air conditioners(**)
R
Rated heating capacity
Declared heating capacity for part load at indoor
T
-
V
T
= bivalent temperature
biv
W
T
= operating limit
OL
For air-to-water heat
X
(if T
OL
Z
Bivalent temperature
Degradation co-efficient
AB
heat pumps(**)
AC
AE
Off mode
AG
Thermostat-off mode
AI
Crankcase heater mode
AK
AL
Capacity control
Sound power level for
AO
cooling mode
(indoor/outdoor)
Sound power level for
AP
heating mode
(indoor/outdoor)
Emissions of nitrogen
AQ
oxides (if applicable)
AT
GWP of the refrigerant
AV Contact details Samsung Electronics, PO Box 12987, Blackrock, Co.Dublin, Ireland
AW
= If Cd is not determined by measurement then the default degradation coefficient shall be 0,25.
**
AX
From 26 September 2018.
***
AY Where information relates to multi-split, the test result and performance data may be obtained on the basis of the performance of the out-door
unit, with a combination of indoor unit(s) recommended by manufacturer or importer.
AZ For multi-split, a list of appropriate indoor units:
III)
Symbol
Value
Unit
(I)
(J)
P
13,4
kW
(M)
rated,c
P
13,4
kW
dc
P
9,9
kW
dc
P
7,0
kW
dc
P
4,2
kW
dc
C
0,25
dc
P
7,8
kW
rated,h
P
6,8
kW
dh
P
4,2
kW
dh
P
3,2
kW
dh
P
3,9
kW
dh
P
7,8
kW
dh
P
7,8
kW
dh
P
-
kW
dh
T
-10
biv
C
0,25
dh
P
0,003
kW
OFF
P
0,05
kW
TO
P
0
kW
CK
Other items
variable
(AM)
L
63 / 70
dB
WA
L
63 / 72
dB
WA
mg/kWh fuel
Nox (***)
-
input GCV
kgCO
2088
(100 years)
Item
(K)
(H)
Seasonal space cooling
N
energy efficiency
Declared energy efficiency ratio for part load
P
-
-
Seasonal space heating
S
energy efficiency
U
-
V
Tj = bivalent temperature
W
Tj = operating limit
For water-to-air heat
Y
(if T
OL
For water-to-air heat
AA
pumps:Operation limit
temperature
-
AD
AF
Back-up heating capacity
AH
Type of energy input
AJ
Standby mode
AK
air flow rate, outdoor
AN
measured
For water/brine-to air heat
pumps: Rated brined or
AS
water flow rate, outdoor
side heat exchanger
(AR)
eq
2
(AU)
II)
Symbol
Value
(I)
220,0
s,c
at given outdoor temperatures Tj
EER
2,9
d
EER
4,3
d
EER
6,1
d
EER
10,3
d
160,0
s,h
COP
2,9
d
COP
3,8
d
COP
5,5
d
COP
6,5
d
COP
2,6
d
COP
1,0
d
COP
-
d
T
-
ol
Supplementary heater
elbu
-
P
0,003
SB
Other items
-
6660
-
-
Unit
(J)
(K)
%
-
-
-
-
%
-
-
-
-
-
-
-
kW
kW
m
/h
3
m
/h
3