Frequency Measurement (Hz) - Chauvin Arnoux F 62 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4.6. Frequency measurement (Hz)

Set the switch to Hz for a
frequency measurement
in AC voltage mode.
Connect the red test
600V CAT
III
100A
cord to the "+" input
Press 2 Sec
HOLD
50 / 60Hz
terminal and the black
OFF
A
mA
test cord to the "COM"
V
input terminal.
Hz
PEAK
ZERO
Then place the probe
tips in contact with the
points where the AC
600 V
voltage is to be
measured.
Read the result on the
display unit.
Disconnect the probe tip
cords from the clamp-on
meter.
Set the switch to Hz for a
frequency measurement
in AC current mode.
600V CAT
III
100A
Press 2 Sec
HOLD
50 / 60Hz
OFF
Open the clamp by
A
mA
pressing the trigger.
V
Hz
PEAK
ZERO
Place the clamp around
the active conductors
(Phase conductors and
Neutral) and release the
600V
trigger; check that the
clamp is properly closed.
Read the measurement
result on the display unit.
Note: The frequency measurement cannot be made if the
clamp-on meter detects both a current measurement and
a voltage measurement.
30
English
F 62

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

F 65

Tabla de contenido