BURNER CLEANING

While the stove is working normally, some automatic cleanings of the burner take place
in 30 minutes intervals. This process consists of cleaning the rest of pellet remaining in
the burner in order to guarantee a proper working of the stove and it takes 30 seconds.
9.4.6

TURNING OFF THE STOVE

In order to turn off the stove, press button no.4 during a few seconds. Once it has
been turned off, it will start the final cleaning stage, in which the pellet supply stops and
the smoke extractor will be working to the maximum speed. This stage would not finish
until the stove has reached the appropriate cooling temperature.
9.4.7

STOVE TURNED OFF

When the stove is turned off, the display shows the following information.
9.4.8

RE-IGNITION OF THE STOVE

When the stove is turned off it would not be possible to restart it up until some safety
time goes by and the stove is cold enough. If you try to start-up the stove, the display
will show up the following information.

10. ALARMS

In case of an anomaly during the operation, the electronics of the stove intervene and highlight the irregularities that have ocurred in the different working
phases, depending on the type of fault.
Every alarm situation blocks the stove. By pressing button 4 we can unblock it. Once the stove has reached the appropriate cooling temperature, the
user can restart it up.
10.1

POWER SUPPLY FAILURE (BLACK OUT)

In the event that power supply is cut for less than 30 seconds, the stove will restart and
continue with its normal working state.
In the event that power supply is cut for greater than 30 seconds, when power is
restored, the stove, as a safety measure, goes straight to the Final Cleaning stage until
the stove temperature reaches the appropriate cooling temperature.Once the final
cleaning has finished, the stove will turn off until the user ignite it again.
10.2

SMOKE TEMPERATURE PROBE ALARM

This alarm goes off when the probe in charge of detecting the exhaust stack
temperature is disconnected or it breaks. During the alarm status, the stove will be in the
turn-off stage.
10.3

SMOKE TEMPERATURE EXCESS ALARM

It goes off when the probe detects a smoke temperature higher than 270°C. Therefore
the display shows the following message.
During the alarm state, the stove will be in the turn-off stage.
10.4

DAMAGED SMOKE EXTRACTION FAN ALARM

It goes off when the smoke extraction fan breaks down. If this happens, the stove does
stop and the display will show up the following alarm. Right after, the turn-off stage will
be immediately activated.
To deactivate the alarm press button 4 and the stove will come to the normal state after
doing the final cleaning.
10.5

IGNITION FAILURE ALARM

In case of ignition failure (after 20 minutes at least) the display will show up an alarm
as follows.
To deactivate the alarm press button 4 and the stove will come to the normal state after
doing the final cleaning.
16:40
22 ºC P-2
BURNER
CLEANING
21:10
23 ºC P-3
FINAL
CLEANING
21:10
22 ºC P-1
OFF
STAND-BY
COOLING
12:42
22 ºC P-3
FINAL
CLEANING
ALARM 2
SMOKE
SENSOR
ALARM 3
ALARM
SMOKE TEMP.
ALARM 4
ASPIRATION
FAILURE
ALARM 5
IGNITION
FAILURE