Descargar Imprimir esta página

KAESER KCF 25 Instrucciones De Montaje Y De Uso página 10

Ocultar thumbs Ver también para KCF 25:

Publicidad

KCF
Climate zone
1 (COLD/MILD)
25
2(MEDIUM/MODERATE)
3 (HOT/TROPICAL)
1 (COLD/MILD)
50
2(MEDIUM/MODERATE)
3 (HOT/TROPICAL)
Climate zone
1 (COLD/MILD)
2(MEDIUM/MODERATE)
3 (HOT/TROPICAL)
* The compressor preformance should be based upon the total scfm flow of all compressors that are piped into the KCF unit.
Technical data
The application, your regional location, climate zone, oil type and oil additives, compressor type, condensate volume changes
sizing of an oil water separator, and the lifetime of the oil water separator cartridge. The sizing correction factors and lifetime of
the cartridge are approximate values only.
Please consult your KAESER COMPRESSORS representative for your KAESER COMPRESSORS certified distributor for
details and sizing assistance.
Function • Descrizione del funzionamento
Fonctionnement • Descrição de funcionamento
1
3
10
Technical data • Datos técnicos
Caracteristiques techniques • Dados ténicos
Compressor Performance*
Piston Compressor
Mineral Oils
Synthetic Oils
90
81
63
180
162
126
Yearly Average
66% RH 45°F
67% RH 55°F
72% RH 75°F
(SCFM)
Rotary Screw Compressor
Mineral Oils
60
113
54
102
42
79
113
225
102
103
79
158
Climate zone
1 shift
2 shift
3 shift
The oil-contaminated condensate can be
fed under pressure to the KCF unit (1).
The pressure is reduced in the pressure
relief chamber (2).
2
The condensate flows steadily into the
subjacent filter stage without turbulence
and runs through the two-stage filter.
The filter unit (3) comprises a prefilter
and a main filter for binding any residual
6
oil constituents. The water flows out of
the KCF oil-water separator through the
water outlet (6) and can be discharged
directly into the sewer system.
A sampling valve (5) is provided so that
the waste water quality can be checked
4
at any time.
1 Condensate inlet
5
2
3
4
5
6
PAO/Diester Oils
Polyglycol Oils
90
60
81
54
63
42
158
113
142
102
111
79
Yearly Average
10-14 months
8-12 months
5-9 months
english
Pressure relief chamber
Filter
Riser duct
Sampling valve
Water outlet
KCF 25, 50

Publicidad

loading

Productos relacionados para KAESER KCF 25

Este manual también es adecuado para:

Kcf 50