Descargar Imprimir esta página

KAESER KCF 25 Instrucciones De Montaje Y De Uso página 20

Ocultar thumbs Ver también para KCF 25:

Publicidad

Maintenance • Mantenimiento
Entretien • Manutenção
*1 EWC 150202
*2 EWC 13 08 02 =
20
European waste disposal key
=
Código de residuos europeo
Code européen de déchet
Europese afvalsleutel
European waste disposal key
Código de residuos europeo
Code européen de déchet
Europese afvalsleutel
english
Procedure
• Step 1. Place new filter set near the
unit. Keep the plastic bag of the new
cartridge for wrapping up the old one.
• Step 2. Shut off the condensate feed
to the unit.
• Step 3. Remove the KCF lid (black cap),
remove filter mat
• Step 4. Remove the Inlet pipe
• Step 5. Lift the old cartridge for the
main tank and allow it to drain. Once
the cartridge has drained place it in
the plastic bag and dispose of the unit
according to your local regulations.
• Step 6. Thoroughly clean the main tank
area with non-abrasive and surfactant-
free cleaner
• Step 7. Insert new cartridge in main
container.
• Step 8. Re-install the inlet pipe and align
the notch on the lid, once inlet pipe is
install insert new filter mat.
• Step 9. Re-install lid (black cap)
• Step 10. MUST BE COMPLETED
before introducing compressed air
condensate to unit. Pour water into unit
from the top through the pressure relief
chamber area.
• Step 11. Stop poring the water (approx.
1 gallon for the KCF 25 & 3 gallons for
the KCF 50) when it starts to come out
at the water outlet that is located on the
side of the unit.
• Step 12. Wait approximately 5 mins
so the cartridge will adsorb some of
the water & add additional water to the
unit until you see water coming out of
the outlet again. Once this has been
accomplished the unit will be recharged
and ready for full operation.
• Step 13. You know can introduce
condensate into unit via the inlet hose
connector on side.
KCF 25, 50

Publicidad

loading

Productos relacionados para KAESER KCF 25

Este manual también es adecuado para:

Kcf 50