Descargar Imprimir esta página

KAESER KCF 25 Instrucciones De Montaje Y De Uso página 16

Ocultar thumbs Ver también para KCF 25:

Publicidad

Putting into operation • Puesta en marcha
Mise en service • Colocação em funcionamento
Utilisation • Operação
16
Operation • Servicio
Fill KCF with clean water
• Take off the cap, remove filter mat from
the pressure relief chamber
• Let in the water through the inlet open-
ing: container and filter chamber are
filling up.
• Shut off the water when it starts to come
water
agua
out at the water outlet.
eau
The water level will sink due to the
água
gradual water intake of the filter.
• Fill up with clean water as required.
• Install again filter mat and presuure
relief chamber
The KCF is ready for operation:
• Compressor condensate can now flow
into the KCF via the pressure relief
chamber.
Note:
Open the outlet of the condensate drain!
Check all connections for leaks!
To ensure trouble-free operation, ob-
serve all the points listed under Main-
tenance:
The constituents of the compressor
condensate will depend on the specific
application.
It is part of the operator's duty of care to
take the necessary precautions, where
appropriate.
english
english
KCF 25, 50

Publicidad

loading

Productos relacionados para KAESER KCF 25

Este manual también es adecuado para:

Kcf 50