SYSTEM LAY-OUT

NORMAL barrier
- Photoelectric cells
- Galvanized column for P.E. cells
- Fotocosta
- Magnetic loop
- Key selector
- Tuned aerial
- Emergency button
T
ECHNICAL CHARACTERISTICS
Lh./rh.irreversible gearmotor used for raising and lowering barrier poles up to 6-
7 m. long.
The upright can be supplied in a painted galvanized version.
The barrier boom can be supplied as one unjointed length or, where headroom
is restricted, it can be requested in an articulated version if you specify the
height of the obstruction above road level.
Besides it can be supplied in one piece with hanging rack.
The barrier boom is designed to be fitted with a pneumatic or photocell safety
strip.
ATTENTION: It is compulsory to conform the barrier characteristics to the
current regulations and laws.
181,10"
118,11"
2755,90"
Measurements in mm/inch
TECHNICAL
DATA
Max. boom lenght
Opening time
Max. torque
EEC Power supply
Motor capacity
Power absorbed
Capacitor
Power supply
Motor capacity
Power absorbed
Capacitor
Normative cycles 230V
Normative cycles 120V
Daily operations suggested
Service
Guaranteed consecutive cycles
Lubrification
Weight of electroreducer
Noise
Working Temperature
Protection IP
1
NORMAL
m.
6-7
s
11
Nm
300
230V~ 50Hz
W
130
A
0,6
6,3
µF
120V~ 60Hz
W
168
A
1,46
20
µF
1000 - 11s/2s
∞ - 11,5s/2s
1000
100%
1000
IP MELLANA 100
kg
145
db
<70
-10 ÷ +55°C
IP
55
G G
B B