TECHNICAL SPECIFICATIONS

Input voltage
Power per meter (without pump)
Electrical current
Maximum pressure
Flow per meter
Recommended height
Weight without water / with water
Protection class
5

FAQS

Question
¿Why is not coming out water of the
curtain with a running order?
Why are there nozzles with water outlet
without image order?
Why is not working the lighting of the
digital curtain?
In other cases or if the answers have not resolved the problem detected, contact a
service engineer (see the list of approved engineers on the product's warranty).
INSTALLATION, OPERATION AND MAINTENANCE MANUAL; DIGITAL
CURTAIN
230 VAC
240 W
1,1 A
0,5 bar
4 m3/h
≤8 m
58/73 kg
IP66
Answer
Check that the control system gives the
order to start the pump.
Check the Ethernet communication
between the electrical panel and digital
curtain.
Check the electrical supply to the
equipment and pump.
Check that there is not any solid inside
the fast acting solenoid valve.
Check the electrical supply. Check that
the DMX lighting program is working
properly.