General Safety; Electrical Safety; Safety In Use And Contact With Water - Astralpool 66548 Manual De Instalación, Operación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

[en]
Fountain Units
1

GENERAL SAFETY

1.1

ELECTRICAL SAFETY

Disconnect the unit from the power supply before doing any assembly or
-
maintenance jobs.
Connect the unit to a power supply with an earth connection, protected by the
following components:
An RCD safety switch with a maximum residual current of 30 mA.
A circuit breaker fuse to the power consumption of 10A.
Use an H07RN-F type waterproof cable.
-
1.2

SAFETY IN USE AND CONTACT WITH WATER

The fountain water must be under the following conditions:
-
Water
characteristics
Temperature
pH
Free residual
chlorine
Total alkalinity
(TAC)
Calcium hardness
(CH)
Salt level
Total dissolved
solids (TDS)
If the temperature is below 4 °C, empty the unit to prevent it from breaking due
-
to the formation of ice inside it.
Do not tamper with the factory-fitted waterproof seals. Otherwise, the unit
-
could lose its warranty.
16
INSTALLATION, OPERATION AND MAINTENANCE MANUAL; DIGITAL
CURTAIN
Minimum
Maximum value
value
4 °C
6.9
0.5 ppm
80 ppm
200 ppm
-
-
35 °C
7.8
2.0 ppm
120 ppm
1,000 ppm
2 g/l
2,000 ppm

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido