Valve terminal
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
This product is recognized by UL. Representative samples
of this component have been evaluated by UL and meet
applicable UL requirements.
Approval information
Product category
NRAQ2 (USA),
YIOZ2 (USA),
code
NRAQ8 (Canada)
YIOZ8 (Canada)
File number
E239998
MH19482
Considered stan-
UL 508, 17th edition,
UL 429, 5th edition
dards
C22.2 No. 142-
M1987
UL mark
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fitting and commissioning to be carried out by qualified
personnel only in accordance with the operating in-
structions.
Such qualified personnel must have several years of
training and experience in installing and commissioning
electrical and pneumatic industrial control systems.
• Please observe the applicable safety requirements
and standards.
Technical data
CPV-10
CPV-10
CPV-14
CPV-18
Turbo
Fluid Type
Air
Permitted
– Storage:
-20 ... +40 °C (-4 ... +104 °F)
tempera-
– Operation, Medium: -5 ... +50 °C (+23 ... +122 °F)
ture range
Maximum
10 bar (145 psi)
Input
Pressure
Coil Ra-
21 V DC,
24 V DC,
tings
Class 2
Class 2
0.46 W
0.65 W
0.65 W
1.50 W
Only for connection to a NEC Class 2 supply
Raccorder Uniquement a un circuit de Classe 2
This device is intended to be used with a Class 2 power
source or Class 2 transformer in accordance with UL1310
or UL1585.
As an alternative a LV/C (Limited Voltage/Current) power
source with one of the following properties can be used:
– This device shall be used with a suitable isolating
source such that the maximum open circuit voltage
potential available to the product is not more than
21 V DC (CPV-18: 24 V DC) and the current is limited to a
value not exceeding 8 amperes measured after 1 mi-
nute of operation.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– This device shall be used with a suitable isolating
source in conjunction with a fuse in accordance with
UL248. The fuse shall be rated max. 4 A and be installed
in the 21 V DC (CPV-18: 24 V DC) power supply to the
device in order to limit the available current.
Note that, when more than one power supply or isolating
device is used, connection in parallel is not permitted.
Extracts )* from the UL reports:
Conditions of acceptability (general):
In determining the acceptability of these valves in the end
use, the following shall be determined:
– The valves and terminals must be provided with a suita-
Note
ble electrical enclosure in accordance with the end-use
standard.
– The supply terminals are not suitable for field-wiring
purposes.
– The suitability of any connectors must be determined in
the end-product.
– The suitability of the valves when used in end-use pro-
ducts that exceed the valves ratings must be investiga-
ted in the end-product.
– Temperatures of the coil windings should be monitored
in the end-product by the change of resistance method
and should not exceed Class A (105 °C / 221 °F) limits.
Conditions of acceptability
(File MH19482, Electrically operated valves):
– The following tests were conducted: Hydrostatic Pres-
sure Withstand Test (five times rated pressure).
– All valves and / or modules have to be supplied by a
NEC Class 2 supply. The supplies may not be electrically
inter-connected at any point within their valve system
circuitry.
)* taken over essentially without important changes
en