6.1.c - Emergency button (Fig. 14)
When pressed, this button impedes the ma-
chine from functioning by disconnecting its
electrical power. In order to disengage the
button (A), turn it in the direction indicated by
the arrow on its head.
WARNING:
Only use the EMERGENCY button (A) in
the event of actual necessity. Do not use
it to shut off the machine: this could lead
to serious machine malfunctions.
6.1.d - Control panel (Fig. 15)
NOTE:
Buttons (8), (9), (10), (11), (12), (13), (14),
are only enabled while the operator is seated
in the driver's seat with the key (6) turned to
the "ON" position.
6) Ignition key
Turned in a clockwise direction to "ON",
it powers the circuits, enabling machine
operation.
Turned in an anti-clockwise direction to
"OFF", it disconnects power to the circuits
and can be removed.
7) Acoustic signal (Fig. 15)
-
Press button (7) to activate the acoustic signal.
8) Suction activation button
16)
-
Press this button to activate the suction
unit. If forward movement or neutral are
enabled, the squeegee will be lowered.
Press the suction activation button again
to deactivate the suction unit. The squee-
gee will be raised and the symbol on the
display will turn off .
9) Brushes button
-
Press this button to lower the brush unit.
-
The brushes will turn when the machine
moves forwards or backwards and they
stop turning when the machine is not
moving.
-
Press this button again to stop the brush-
es and raise the brush unit. The symbol
on the display will turn off.
(Fig.
(Fig. 17)
EN - 17
7
14
8
10
13
24.5
24.5
EN
A
Fig. 14
6
9
12
11
Fig. 15
00000:12
Fig. 16
00000:12
Fig. 17