Coolant Check; Substituting The Rubber And Teflon; Adjusting The Cams; Changing The Sealing Blade - Minipack-Torre FM76A Digit Instrucciones Para La Instalación, Uso Y Mantenimento

Ocultar thumbs Ver también para FM76A Digit:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
Chapter 7. Ordinary maintenance

7.5. Coolant check

Every 4 months check the coolant level by unscrewing the cap (35) (figure 7.5. page 70). Check that the rod is made wet
by the liquid for about 2 cm height, otherwise add a mixture of water and antifreeze liquid (10%).

7.6. Substituting the rubber and Teflon

When the Teflon-strikers (36) are worn out, substitute them with spare parts, making sure the application is linear and
even (figure 7.6. page 70). Before applying the Teflon self-adhesive strip clean the rubber part (37) with a detergent.
If the rubber (37) is also damaged, substitute it as follows:
1.
remove the old rubber
2.
clean its housing
3.
apply some drops of glue in the housing
4.
insert the new rubber in a linear way
5.
clean the rubber with a detergent
6.
apply the self-adhesive Teflon-strip.

7.7. Adjusting the cams

Cams must only be adjusted by authorised personnel!
It is necessary to disassemble the panel (38) at the back of the machine in order to get access to the cams (figure 7.7.A page 70).
There are 4 cams which control (figure 7.7.B page 70):
1.
The lowering of the upper hood and so its pressure on the sealing blade.
2.
The maximum opening of the upper hood and the start of the conveyor belt.
3.
Overriding activation of the safety device on the sealing frame (
4.
Detachment of the upper hood immediately after sealing.
The adjustment is made by loosening the screw (39) and rotating the cam to the correct position.
Attention: adjust cam gradually with small movements!

7.8. Changing the sealing blade

To substitute the sealing blade (27) follow this procedure (figure 7.8. page 70):
Disconnect power to the machine
Unscrew the three screws (40), (41), (42)
Remove the old sealing blade
Clean the housing and if necessary substitute the insulating Teflon (43) of the central clamp
Insert the new sealing blade starting from the central clamp and tighten the screw (41)
Trim the new sealing blade according to the holes of the pistons (44) and (45)
Complete the insertion if the sealing blade in the whole housing
Push the rear piston completely (45) towards the sealing blade to make it enter the hole of the piston itself and then
tighten screw (42)
Push the front piston (44) completely towards the sealing blade to make it enter the hole of the piston itself and then
tighten screw (40)
Trim the Teflon projecting from the central clamp
Make sure that the sealing blade is well positioned and under tension

7.9. Wiring diagram

(figure 7.9. page 71/72).
B1
Hood descent limit switch
B2
Hood rise limit switch
B3
Safety device override limit switch
B4
Hood detachment limit switch
B5
Safety limit switch
B6
Rewinder limit switch
BT1
Thermocouple
E1/2
Cooling fan
ER1
Sealing blade heater
ER2/3 Heaters
F1
Sealing blade / resistors fuse
F2
Fan / belt / hood motor fuse
F3
Auxiliary transformer fuse
F4
Fan / pump motor fuse
FU1
Board fuse
5X20
K1
Power module
M1
Fan motor
M2
Belt motor
M3
Hood motor
10.3X38
10.3X38
10.3X38
5X20
5 mm before the sealing).
M4
Cooling pump motor
M5
Rewinder motor
Q1
Main switch
Q2
Rewinder switch
QM1 Sealing blade contactor
QM2 Heaters contactor
QM3 Fan motor contactor
QM4 Belt motor contactor
QM5 Hood descent contactor
QM6 Hood rise contactor
QM7 Accessories contactor
S0
Emergency pushbutton
S1
Start button
S2
Manual selector
SK1
Control board
T1
Cutting transformer
T2
Auxiliary transformer
X1
Rewinder power supply socket
X2
Rewinder power supply plug
17