A - CONNEXIONS
IT IS COMPULSORY TO SET THE
DIP 13 OF THE CONTROL PANEL
IN THE ON POSITION.
T1
T2
JA
T T R
S
T
N
U
V
W
3-PHASE LINE
400V + N
MOTOR
3 P
PTO
J1
L1 - N
230 Vac 50/60Hz power supply (120Vac 60Hz upon request)
J2
Flashing light (max 40W )
U
Motor common connection
V-W
Motor phases and capacitor connections
J3
R-AUX
Auxiliary relay contact (NO) Max 700 W
SIGNAL
Gate open state (24 Vdc 3 W max)
COM A+
Common contacts / Positive 24 Vdc
J4
A+ COM
+ 24Vdc accessories power supply / Common contacts
A-
- 24Vdc accessories power supply
A+ TEST
+ 24Vdc photocells self-test power supply
J5
COM A+
Common contacts / Positive 24 Vdc
B.I.O.
Contact (NO) dedicated to a clock
PED.
Pedestrian opening contact (NO)
START
Single pulse contact (NO)
CLOSE
Closing impulse contact (NO)
OPEN
Opening impulse contact (NO)
J6
COM A+
Common contacts / Positive 24 Vdc
STOP
STOP impulse contact (NC)
PHOT 1
Photocells contact 1 (NC)
PHOT 2
Photocells contact 2 (NC)
EDGE 1
Edge 1 contact (NC)
EDGE 2
Edge 2 contact (NC)
J7
COM A+
Common contacts / Positive 24 Vdc
LIMIT SWITCH
Limit switches that cuts off the motor
J8
J7
J6
J5
J4
J3
J2
J1
F1
PROG
J11
J12
J13
J14
J15
J16
J17
J8
PROBE
IS NOT AVAILABLE
J9
ENCODER
IS NOT AVAILABLE
J10
RS485 termination of J11
J11
APP+
Connector for APP+ card
J12
APP
Connector for APP card
J13
SERIAL COM /
Connector for serial connection
SYNC
J14
-
-
J15
RADIO
Connector for radio module ACG8069
J16
RADIO
Connector for radio receiver RIB, 24 Vdc supply
J17
433 MHz Radio antenna
PROG.
Programming button
TCA
Trimmer for automatic closing time adjustment (DISABLED
DEFAULT AND DL11 LED OFF)
LOW SP
IS NOT AVAILABLE
TORQUE
IS NOT AVAILABLE
F1
T5A
Fuse for motor protection
T1 - T2 T
POWER RELAYS FOR THE COMMAND OF THE MOTOR
JA
R-N
SINGLE PHASE POWER SUPPLY - NEUTRAL
CONTACTS FOR THE EARTH CONECTION
U-V-W
MOTOR CONNECTION
33
INNER THERMAL OVERLOAD CUT-OUT
SWITCHES (per CEI 2-3/IEC 34-1)
The electrical protections on the SUPER 6000
motor power line may not be sufficient to protect
against overloads. If the cooling conditions worsen,
the motor overheats but the electrical conditions
do not change, which inhibits line protections.
Installing the bimetallic device PTO on the L1/
R4-CRX control panel solves this problem.
This is a normally-closed electromechanical device
that opens when the threshold
temperature is reached; it
automatically resets when the
temperature falls below the
threshold level.
T T
G
B
T T

Publicidad