3.3 Connection cable

• The hob is supplied with a connection
cable.
• To replace the damaged mains cable,
use the cable type: H05V2V2-F which
withstands a temperature of 90°C or
higher. Speak to your local Service
Centre.
3.4 Assembly
min.
500mm
min.
12

3.5 Protection box

min.
50mm
If you use a protection box (an additional
accessory), the protective floor directly
below the hob is not necessary. The
protection box accessory may not be
available in some countries. Please
contact your local supplier.
min.
28
You can not use the
protection box if you install
the hob above an oven.