Installation Of The Indoor Unit; Standard Mounting - Acson international CEEW Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
Disposal requirements
Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall
not be mixed with unsorted household waste.
Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant,
of oil and of other parts must be done by a qualified installer in accordance with relevant local and national legislation.
Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring
this product is disposed of correctly, you will help to prevent potential negative consequences for the environment
and human health. Please contact the installer or local authority for more information.
Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local
and national legislation.
1. Preliminary Site Survey
Electrical supply and installation shall conform to the
local authority (e.g. National Electrical Board).
Voltage supply fluctuation must not exceed ±10% of
the rated voltage. Electricity supply lines must be
independent of welding transformers which can cause
high supply fluctuation.
Ensure that the installation location is convenient for
wiring and piping.

2. Standard Mounting

Figure A
1073.0
268.0
535.5
Figure B
Ensure that the overhead supports are strong enough
to hold the weight of the unit.
Position the hanger rods (wall mounting bracket for
floor standing), and check for its alignment with the
unit as shown in Figure A.
Also, check that the hangers are secured and the base
of the fan coil unit is leveled in both horizontal
directions, taking into account the gradient for drainage
flow as recommended in Figure B.
NOTICE

INSTALLATION OF THE INDOOR UNIT

2
Min
300.0mm
Ceiling Type
Figure C
Min 400.0mm
Floor Standing Type
Please ensure that the following steps are taken:
Check the gradient for drainage flow as recommended
in Figure B.
Provide clearance for easy servicing and optimal air
flow as shown in Figure C.
The indoor unit must be installed such that there is no
short circuit of the cool discharge air with the warm
return air.
Do not install the indoor unit where there is direct
sunlight shining on the unit. The location should be
suitable for piping and drainage installation. The unit
must be a large distance away from the door.
Min 250.0mm
Utensils, Furnitures Or
Built-In
Architectural
Features Must Not Protrude
More Than 250.0mm
Min 1.0m