Specifications • Installation
Electrical shock hazard. Can burn or
kill. If your basement has water or moisture on
floor, do not walk on wet area until all power has
been turned off. If shut-off box is in basement, call
electric company or hydro authority to shut-off
service to house, or call your local fire department
for instructions. Remove pump and repair or re place.
Failure to follow this warning can result in fatal
electrical shock.
17. Pump water only with this pump. Do not use with salt
water or brine.
18. Do not install the pump in any location classified as
hazardous by the National Electric Code, ANSI/NFPA
70-1984 or the Canadian Electrical Code.
Specifications
Power supply required. . . . . . . . . . . . . . . . . . . . . . . . . . . . 115V, 60 HZ.
Liquid Temp. Range . . . . . . . . . . . . . . . . . . . . 32°F to 130°F (0°-54°C)
Individual Branch MDC33 Series . . . . . . . . . . . . . . . . . . . . 15 Amps
Circuit Required:
MDC50 Series . . . . . . . . . . . . . . . . . . . .20 Amps
Discharge Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1/2" NPT
Performance
GPM (LPM) at total feet (m)
Model
5 (1.5m)
10 (3)
Capacity gallons (liters)/minute
MDC33
48 (182)
40 (151)
MDC50
62 (235)
53 (201)
Motor, Switch, & Cord Specifications
Model #
HP
MDC33P1
1/3
MDC33V1
1/3
MDC33D1
1/3
MDC33PC1 20
1/3
MDC33V1 20
1/3
MDC33D1 20
1/3
MDC33PC1 30
1/3
MDC50P1
1/2
MDC50V1
1/2
MDC50D1
1/2
MDC5010M
1/2
MDC50PC1
1/2
MDC50VC1
1/2
MDC50D1 20
1/2
*Piggyback plug
15 (4.6)
20 (6.1)
25 (7.6)
30 (9.2)
29 (110)
15 (57)
-
46 (174)
38 (144)
29 (110)
10 (37.9)
VOLTS
PHASE
115
1
115
1
115
1
115
1
115
1
115
1
115
1
115
1
115
1
115
1
115
1
115
1
115
1
115
1
Installation
1.
Install the pump in a sump pit with a minimum
diameter of 12" (305 mm) for models equipped
with vertical and diaphragm float switch models,
and 14" (356 mm) for tethered float switch models.
The sump depth should be 15" minimum (381mm).
Construct the sump pit of tile, concrete, steel or
plastic. Check the local codes for approved materials.
2. NOTICE: When installing the vertical switch, the rod
stop (Ref. No. 1F, Repair Parts) must not be pushed up
farther than the bottom nib on the float rod. Pushing
it any farther up the rod will cause the switch to hang
up on the pump discharge and will damage the pump.
No flow
at height
shown
below
24 ft.
Figure 1
-
(7.3m)
3. The pump should not be installed on clay, earth or
32 ft.
(9.8m)
sand surfaces. Clean the sump pit of small stones
and gravel which could clog the pump. Keep the
pump inlet screen clear.
AMPS
DISCHARGE
9.8
1-1/2" NPT
9.8
1-1/2" NPT
9.8
1-1/2" NPT
9.8
1-1/2" NPT
9.8
1-1/2" NPT
9.8
1-1/2" NPT
9.8
1-1/2" NPT
12.0
1-1/2" NPT
12.0
1-1/2" NPT
12.0
1-1/2" NPT
12.0
1-1/2" NPT
12.0
1-1/2" NPT
12.0
1-1/2" NPT
12.0
1-1/2" NPT
5669 0707
SWITCH
CORD
Tethered*
10' (3.1 m)
Vertical*
10' (3.1 m)
Diaphragm*
10' (3.1 m)
Tethered*
20' (6.1 m)
Vertical*
20' (6.1 m)
Diaphragm*
20' (6.1 m)
Tethered*
30' (9.1 m)
Tethered*
10' (3.1 m)
Vertical*
10' (3.1 m)
Diaphragm*
10' (3.1 m)
Manual
10' (3.1 m)
Tethered*
20' (6.1 m)
Vertical*
20' (6.1 m)
Diaphragm*
20' (6.1 m)
3
WT.
25 (11.4 kg)
25 (11.4 kg)
25 (11.4 kg)
25 (11.4 kg)
25 (11.4 kg)
25 (11.4 kg)
25 (11.4 kg)
25 (11.4 kg)
25 (11.4 kg)
25 (11.4 kg)
25 (11.4 kg)
25 (11.4 kg)
25 (11.4 kg)
25 (11.4 kg)