Installation

A-OFFSET INSTALLATION
PLASTIC PIPE SHOWN
Figure 1: Offset Installation
readless
oupling
Pipe
Pipe
th Ejector)
er
B-OVER THE WELL INSTALLATION
STEEL PIPE SHOWN
Figure 2: Over the Well Installation
Pump
Gasket
Adapter Flange
Threadless
Sanitary
Coupling
Well Seal
Steel Pipe Nipple
Coupling
1" Plastic Drive Pipe
1-1/4" Plastic Suction Pipe
Special 1-1/4" Plastic Pipe
Adapter. (Supplied with Ejector)
1" Plastic Pipe Adapter
Ejector Assembly
Foot Valve & Strainer
Pump
Gasket
Adapter Flange
Threadless Coupling
Sanitary
Well Seal
1" Drive Pipe
1-1/4" Suction Pipe
Ejector Assembly
Foot Valve & Strainer
474 0194
BEFORE YOU INSTALL YOUR PUMP
Pump
NOTE: For proper performance, pump MUST be matched to ejector and
Gasket
to well depth. Use this pump on wells from 25 ft. depth to water to 130 ft.
Adapter Flange
depth to water.
Step 1. Long runs and many fittings increase friction and reduce flow.
Threadless Coupling
Locate pump as close to well as possible: use as few elbows and
fittings as possible.
Sanitary
Step 2. Be sure well is clear of sand. Sand will plug the pump and void
Well Seal
the warranty.
Step 3. Protect pump and all piping from freezing. Freezing will split pipe,
damage pump and void the warranty. Check locally for frost pro-
1" Drive Pipe
tection requirements (usually pipe must be 12" below frost line
and pump must be insulated).
1-1/4" Suction Pipe
Step 4. Be sure all pipes and foot valve are clean and in good condition.
Step 5. No air pockets in suction pipe.
Step 6. No leaks in suction pipe. Use PTFE pipe thread sealant tape to seal
Ejector Assembly
pipe joints.
Step 7. Unions installed near pump and well will aid in servicing. Leave
room to use wrenches.
Foot Valve & Strainer
Step 8. Plug 1" drive port when installing on shallow well.
IMPORTANT: Flow into well must at least equal flow out through
B-OVER THE WELL INSTALLATION
pump!
STEEL PIPE SHOWN
PIPING IN THE DEEP WELL
See Figures 1 and 2.
NOTE: Deep well installations are either single pipe (2" wells) or double
pipe (4" and larger wells). In a double pipe installation, the larger pipe is
the suction pipe and the smaller pipe is the drive pipe (very deep wells may
use suction and drive pipes of the same diameter).
Plastic pipe is ideal for double pipe installations. Due to its light weight, it
is easy to handle and does not usually require a block and tackle for instal-
lation and removal.
PLASTIC PIPE INSTALLATION – DOUBLE PIPE
NOTE: Use PTFE pipe thread sealant tape on all male threads on plastic
pipe and fittings to prevent air leaks in suction piping.
Step 1. Inspect ejector to make sure that nozzle and venturi openings are
clean and clear.
Step 2. Inspect pipe for any foreign matter or obstructions.
IMPORTANT: Make sure that no foreign matter enters pipe openings while
installing pump.
Step 3. Make sure foot valve operates freely: attach to ejector with a close
nipple. Use PTFE pipe thread sealant tape on male threads.
Step 4. Install nozzle and venturi in deep well ejector.
Step 5. Using PTFE pipe thread sealant tape on male threads, install spe-
cial plastic pipe adapter (supplied with ejector) by screwing adapt-
er into 1-1/4" tapped hole in ejector body (see Figure 1).
Step 6. Thread a 1" plastic pipe adapter into the 1" tapped hole in ejector
body (see Figure 1).
474 0194