Light; Automatic Closing - BelFox 47-21-i Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

9.15. Light

In this menu item, you can set whether and for how long the light (termi-
nals 5 & 6) will be illuminated after the motor has run. The afterglow du-
ration can be set from 0-99 seconds in increments of seconds, then from
2-10 minutes in increments of minutes.
After glow
0sec-10min (Continue pressing the <+> key for further
settings.)
End position
Output activates as soon as an end position is reached.
End position
Output activates as soon as the end position Open is
Open
reached.
End position
Output activates as soon as the end position Closed is
Closed
reached.
The light is always on when the motor is operating, except when setting
the end position.
It can be tested with the buttons<+> and <->.

9.16. Automatic closing

In this menu item you can set whether and after what time an automatic
closing starts. The duration until automatic closing (AC) can be set from
0-99 seconds in increments of seconds, then from 2-10 minutes in
increments of minutes. Furthermore, the time until automatic closing can
be set from 0 to 20 seconds after the light barrier has been released. If a
time is entered here, the control always tries to close the gate, when the
light barrier is left.
Note: Automatic closing can be switched on and off via input D (input D:
Auto Close OFF).
28

Publicidad

Tabla de contenido
loading

Tabla de contenido