Charging Process; Setup Menu - Würth Acctivia Expert 12/24 V 35 A Traducción De Las Instrucciones De Uso Originales

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
If necessary, manually correct the battery voltage
using the start/stop button (for example with a
deeply discharged 24 V battery)
If the Stop/Start button is not pressed again,
3
charging starts automatically after 5 seconds.

Charging process

Attention!
Risk of damage to the device and accessories.
The indicated charging voltage must match the
¾
battery voltage.
If necessary, correct the charging voltage using
¾
the Stop/Start button.
The increasing charging state LEDs represent the
battery's charge.
Trickle charging:
Once the battery is fully charged, the charger
switches automatically to trickle charging, to
compensate for the battery's self-discharging.
The battery can remain connected to the charger
indefinitely.
Risk of sparking if the charging terminals
are disconnected too early.
End charging by pressing the Stop/
¾
Start button.
Press the Stop/Start button to end charging.
Disconnect the charging cable (black) from the
battery negative terminal (-).
Disconnect the charging cable (red) from the
battery positive terminal (+).
Stopping charging
To stop charging, press the Stop/Start button.
Charging stops.
3
The operation mode indicator for the selected
3
charging voltage flashes.
Restarting charging
To continue charging, press the Stop/Start button.
The operation mode indicator for the selected
3
charging voltage lights up.
16
CAUTION!

Setup menu

Information
The following chapter is only applica-
ble to the LED version of the standard
operating panel.
In the setup menu, select the characteristic curve
type according to the type of battery to be
charged or the requirement, in accordance with
the "Characteristic curve" chapter.
Information
Do not connect the charging cable to
the battery. It is not possible to select
the type of characteristic curve if the
charging terminals are connected.
Connect the mains lead to the charger and plug
into the mains
The charger is in no load mode - both ready-
for-use indicators light up
Press the Stop/Start button for about 10 seconds
to open the setup menu
Both ready-for-use indicators go out.
3
The charger is in setup mode.
3
Additionally, the set type of characteristic curve is
3
indicated on the display.
Selecting the characteristic curve type
Press the stop/start button, to select the character-
istic curve type according to the "Characteristic
curve" chapter.
If there is no further selection in the next 10 sec-
3
onds, the selected characteristic curve type is
saved.
Information
Do not connect any battery during the
10 second period. If a battery is connect-
ed during this 10 second interval, the
characteristic curve type is not saved.
Both ready-for-use indicators light up.
3
The charger is automatically ready for the next
3
charging with the newly selected characteristic
curve type.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

0510 955 604

Tabla de contenido