Descargar Imprimir esta página

Mastervolt 70405030 Manual De Utilización página 2

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Product description and application
The CC is designed to read out the actual charge current of a Mastervolt charger and to set a limit for
the charge current to prevent the external AC source from an overload situation.
Operation
The State of charge gauge indicates the stage
of the charge process. Refer to the charger
manual.
LED
Meaning
1
Charger on, I=max (BULK)
1 and 2
Uout>13.8/27.6/55.2V, I=max
1 till 3
Uout>14.25/28.5/57V, I<max (ABS)
1 till 4
45 min. after start, max. bulk timer,
or I<return amps.
All 5
6 hours after start, max. bulk timer,
or I<return amps for 15min or longer
(FLOAT)
The Output gauge indicates the actual
charge current in relation to the
maximum available charge current.
Example: The used charger is a 12/80.
The maximum charge current is 80A
which corresponds with 100%. If
charge current is only 40A then the
Output gauge indicates 50%.
The Current control LED illuminates if
the charge current is limited.
ENGLISH
Easy programming in thee steps
Steps to set a limit for the charge current:
1.
Hold Set pressed until the Output
indicator starts to blink, indicating
the present setting.
2.
Now press Set repeatedly to scroll
along the set points. See table 2.
3.
Don't press the button anymore
once the desired value is chosen.
After 3 seconds the value is stored
and the indicator stops blinking.
After a few seconds the actual
charge current is displayed again.
When the charger is switched on
the Charger present indicator
illuminates.
In case of a failure the Failure
indicator illuminates. See table 1:
failure codes.

Publicidad

loading