Wired Controller XK49
(1) Before installation, please cut off the power for indoor unit.
(2) Pull out the 2-core twisted pair line connected with the indoor unit from the
mounting hole and separately fix the twisted pair on the H1 and H2 terminal
by screws.
(3) Gate-control wiring notice:
1) If the gate-control system is not involved, turn the No.1 switch of the DIP
switch S1 to the number side which is located at the bottom of the wired
controller.
2) If the gate-control system is connected, make sure the No.1 switch of the
DIP switch S1 is turned to the "ON" side. Connect the gate-control terminal
to the N and L port or the VCC and GND port. Attention to the following
items:
a)
The N and L port is the power supply interface of the
100-240V~50/60Hz gate control.
b)
The VCC and GND port is the power supply interface of the DC 5-24V
gate control.
c)
Only one power input can be chosen between the 100-240V~50/60Hz
and the DC 5-24V.
(4) After finishing the wiring, set the wired controller soleplate on the wall and
use the M4X25 screws to fix it with the mounting hole.
(5) Insert the wiring on the soleplate to the socket CN1 on the control panel and
then buckle the soleplate and the panel together.