GYSPACK cannot start the
vehicle, and the red light is
off.
Orange and green lights are
flashing after 24h or charge.
Orange and green lights
flash alternatively during the
charge
The orange led flashes for
more than 3hours and does
not turn to green.
Gyspack Pro is plugged in to
the mains but no light is on.
GYSPACK PRO 12.24
The battery voltage is
incorrect
Internal batteries voltage
is really low. They can be
damaged.
Internal batteries are
damaged. Voltage of
batteries does not
increase despite the
charge.
Thermal protection of the
charger
The battery is sulphated
or deeply discharged.
No voltage from the
mains.
The voltage connector is
not plugged on the 12V
socket.
The fuse has blown
Check that the selected voltage
corresponds to the voltage of the
vehicle's battery
Put the GYSPACK on recharge to
attempt recovery of internal
batteries.
Unplug the machine from the
mains, and then restart the
charge. If the problem persists
the batteries are damaged.
Charger is overheating because
the temperature is too high. The
charger will restart the charge
automatically as soon as the
temperature dropped down
sufficiently.
Normal process of the Gyspack
Pro: the charger detects the
presence of sulphated / deeply
discharged
batteries.
attempt to recover the battery
with a specific charge of 16h.
Check the presence of 230V
voltage on the supply.
Plug the voltazge connector on
the 12V socket.
Replace the fuse.