7. High-Speed Cooling Fan
8. Thermal Protection
9. Surge Protection
10. Low-Battery Protection
3.
BEfORE USING YOUR POWER INVERTER
When you turn on a device or a tool that runs on a mo-
tor, the device basically goes through two stages:
1. Start Up – Requiring an initial surge of power (com-
monly known as the "starting or peak load").
2. Continuous Operation – Power consumption drops
(commonly known as the "continuous load").
The wattage (WATTS) or amperes (AMPS) can normally
be found stamped or printed on most devices and equip-
ment, or in the user's manual. Otherwise, contact the
manufacturer to find out whether the device you want to
use is compatible with a modified sine wave.
To calculate the wattage: Wattage = AMPS x 120 (AC
Voltage).
To calculate the starting load: Starting Load = 2 x
WATTS. In general, the start up load of the device or
power tool determines whether your inverter has the
capability to power it.
To calculate the continuous load: Continuous Load =
AMPS x 120 (AC Voltage).
Attention: Always run a test to establish whether the
inverter will operate a particular piece of equipment or
device. In the event of a power overload, the inverter is
7 •
•