BFT VEGA - VEGA ULTRA Manual Del Usuario página 33

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 60
x2
***
0---
10--
ALT
follow the user guide
Add. 1ch
Add. 2ch
Add. 3ch
Add. 4ch
erase 64
erase 1
language
autoset
l.sw adj
closing
opening m1
opening m2
stat
vers
OK
- +
No total manoeuvres(in hundreds)
n. cycles
OK
- +
No radio controldevices memorised
OK
n. remotes
- +
List of last 30 errors
err
OK
0---
password
34
- VEGA - VEGA ULTRA
ACCESS MENUS Fig. 2
INSTALLATION MANUAL
150-
1520
See PARAMETERS MENU
See LOGIC MENU
hidden butt
release
desired button
hidden butt
release
desired button
hidden butt
release
desired button
hidden butt
release
desired button
If cancelled
ok
If not present
( 0001 )
KO
If clone, it is disabled
dis
swc position
( 0000 )
( 0000 )
ONLY FOR PHEBE ULTRA
Control unit
software version
bft . . .
+/-
0000
+/-
00
+/-
01. 3 3
02. 0 1
........
30. 1 5
+/-
10--
150-
ok
See RADIO MENU
Diagnostics
DESCRIPTION
code
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
PED pedestrian input activated
PED
TIMER input activated
TIME
STOP input activated
STOP
PHOT photocell input activated
PHOT
PHOT OP opening photocell input activated
PHOP
PHOT CL closing photocell input activated
PHCL
BAR safety edge input activated
BAR
Activation of BAR safety edge input with ACTIVE
reversal ONLY WHILE OPENING, or, if con gured
baro
as veri ed safety edge active only while open-
ing, Activation of the associated FAULT input
Activation of BAR safety edge input with ACTIVE
reversal ONLY WHILE CLOSING, or, if con gured
barc
as veri ed safety edge active only while clos-
ing, Activation of the associated FAULT input
SWC motor closing limit switch input
SWC
activated
SWO motor opening limit switch input
SWO
activated
SWO2 motor 2 opening limit switch input
SWO2
activated
The board is standing by to perform a
complete opening-closing cycle uninter-
rupted by intermediate stops in order to
SET
acquire the torque required for movement.
WARNING! Obstacle detection not active
Photocell test failed
ER01
Safety edge test failed
ER02
Opening photocell test failed
ER03
Closing photocell test failed
ER04
8k2 safety edge test failed
er06
Board hardware test error
ER1x*
Encoder error
ER2x*
Reverse due to obstacle - Amperostop
ER3x*
Thermal cutout
ER4x*
ER70
ER71
Internal system supervision control error.
ER74,
ER75
Consistency error of the control unit's parame-
ER72
ters (Logics and Parameters)
D-track parameter error
ER73
Limit switch error
ERf0
Limit switch error always active after ope-
erf1
ration start
Solenoid lock output overload
erf9
* X = 0,1,...,9,A,B,C,D,E,F
1520
prg
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
NOTES
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Check photocell connection and/or
logic settings
Check safety edge connection and/
or logic settings
Check photocell connection and/or
parameter/logic setting
Check photocell connection and/or
parameter/logic setting
Check safety edge connection and/or
parameter/logic settings
- Check connections to motor
- Hardware problems with board
(contact technical assistance)
- Motor power or encoder signal cables
inverted/disconnected.
- Actuator movement is too slow or
stopped with respect to programmed
operation.
Check for obstacles in path
Allow automated device to cool
Try switching the board o and back
on again. If the problem persists,
contact the technical assistance
department.
Pressing OK the detected settings are
con rmed. The board will keep on
working with the detected settings.
The board settings must be
checked (Parameters and Logics)
Pressing OK, the board will keep on
working with D-track as a default.
An autoset is required
check limit switch connections
Check limit switch and motor con-
nections
-Check lock connections
- Unsuitable lock

Publicidad

Tabla de contenido
loading

Tabla de contenido