TABLE "A" PARAMETERS MENU - PARA
Parameter
min.
max.
120
TCA
TRF. L GHT.
1
180
CLR. T
30
250
t. start
1
240
output time
OP. D IST.
 1
50
SLOUD
CL. D IST.
 5
50
SLOUD
 0
50
DIST. D ECEL
PARTIAL
10
99
OPENING
SWC pressu-
1
99
re force
99
OP. F ORCE
 1
99
CLS. F ORCE
 15
99
OP SPEED
 15
99
CL SPEED
SLOW SPEED
15 
50
0
250
Maintenance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
38
- VEGA - VEGA ULTRA
INSTALLATION MANUAL
Default
Personal
De nition
Automatic
120
closing time [s]
Time-to-clear
tra c light zone
40
[s]
150
Inrush time
Activation time of
the timed output
10
[s]
Slow-down
10
distance during
opening [%]
Slow-down
distance during
10
closing [%]
Deceleration
15
distance [%]
Partial opening
40
[%]
Leaf pressure for-
ce on the closure
20
limit-switch [%]
Leaf force during
50
opening [%]
Leaf force during
50
closing [%]
Opening speed
99
[%}
Closing speed
70
[%]
Slow-down
20
speed [%]
Programming
number of
operations for
0
maintenance
threshold
[in hundreds]
Waiting time before automatic closing.
Time-to-clear for the zone run through by tra c controlled by the tra c light.
Inrush time at each motor startup, during which obstacle detection is not active. Given in hun-
dredths of a second (150=1.5 s).
Activation length of timed radio channel output in seconds
Slow-down distance for motor(s) during opening, given as a percentage of total
travel. WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Slow-down distance for motor(s) during closing, given as a percentage of total travel.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Deceleration distance (switch from running speed to slow-down speed) for motor(s) both
during opening and during closing, given as a percentage of total travel. WARNING: Once the
parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Partial opening distance as a percentage of total opening following activation of PED pedestrian
command.
The force exerted by the leaf during the pressure on the closure limit-switch.
Force exerted by leaf during opening. This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated), before an
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It a ects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety
devices where necessary (**).
Force exerted by leaf during closing. This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated), before an
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It a ects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety
devices where necessary (**).
Percentage of maximum speed that can be reached by motor(s) during opening.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required. WARNING: when the display reads "SET",
obstacle detection is not active.
Percentage of maximum speed that can be reached by motor(s) during closing.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required. WARNING: when the display reads "SET",
obstacle detection is not active.
Opening and closing speed of motor(s) during slow-down stage, given as a percentage of
maximum running speed. WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: When the display reads
""SET"", obstacle detection is not active.
Allows you to set a number of operations after which the need for maintenance will be repor-
ted on the AUX output con gured as Maintenance or Flashing Light and Maintenance .
Description